Справочник Пользователя для Majestic Appliances UVS36RN

Скачать
Страница из 24
10
UVS33/36 Vent-Free Heaters
20002211
W584-9
WIRING DIAGRAM
1/8/99   djt
11/9/99 added thermopile
Fig. 13  Remote switch wiring.
W584-9
Thermopile
FP381
DVT access door
12/99
FP381
Fig. 14  Installing remote switch bracket.
Alternate Switch Location
Remote switch can be installed on either side of the 
access door.  Simply mount the switch to the switch 
bracket provided.  Screw the bracket on either side of 
the frame, lining up the screws with the pre-punched 
holes. (Fig. 14) 
Finishing
CAUTION: All joints between the finished wall 
and the heater surround (top and sides) may 
be sealed only with noncombustible material. 
Only noncombustible material can be applied 
as facing to the heater surround (the black 
painted face). 
When finishing the heater, never obstruct or modify the 
air inlet/outlet top or bottom grilles in any manner.
Finish the wall with the material of your choice. Main-
tain minimum clearances when installing a combustible 
mantel or other combustible projection.