Справочник Пользователя для Aprilaire 600 &700

Скачать
Страница из 19
- 12 -
1. Note humidistat or control setting and turn dial to the “OFF” position.
2. Turn off water supply.
3. Press the tabs in the latches on the top and bottom of front cover (1) and pull cover off
base with both hands. Set aside.
4. Carefully pull the plastic feed tube (2) out of the distribution tray (5) at the top of the
Water  Panel  evaporator  assembly  (4).  Pull  this  assembly  out  by  grasping  at  top  and
tipping out.
5. Remove  the  black  distribution  tray  (5)  from  the  water  panel  evaporator  assembly  by
lifting  straight  up  from  the  scale  control  insert  (8).  Lightly  scrape  out  any  calcium
deposits and clean the “V” notches (6) but do not scrape off the granular coating
from  the  bottom. 
This  textured  surface  helps  ensure  even  water  flow  for  maximum
performance. See page 2 if removed. 
6. Slide the Water Panel evaporator (7) out from the white plastic Scale Control Insert (8).
Clean the insert frame of calcium deposits with a putty knife. Inspect Water Panel evap-
orator (Stock No. 35 for Model 600) and substitute a new Genuine Aprilaire Water Panel
if necessary. Slide the Water Panel back into the scale control insert with the black col-
ored spot up and snap the black distribution tray back into place.
7. Re-install the Water Panel evaporator assembly into the unit by fitting its drain tube into
the round receptacle at the base of the unit. Push the assembly in at the top against the
beveled tabs that will hold it in place. Push the end of the feed tube back firmly into the
distribution tray and replace the front cover.
8. Remove the drain hose (9) from the bottom of the unit and bend and flex it to loosen
the internal calcium deposits. Then flush it with water under pressure and slip it back
onto the drain fitting.
9. Turn on the water supply.
10. Check system operation:
Humidifier Control: (Automatic or Manual) Check system operation by set-
ting the knob to “Test.” With furnace blower operating and furnace calling
for  heat,  humidifier  will  operate  for  one  minute.  DO  NOT  LEAVE  IN  TEST
MODE AS HUMIDIFIER WILL NOT OPERATE.
11. Set Humidifier Control to its original position.
MAINTENANCE INSTRUCTIONS
for
APRILAIRE HUMIDIFIER MODEL 600
CAUTION!    Sudden  operation  may  cause  personal  injury  or  property  damage.
Turn humidistat or control to “off” or lowest setting before servicing.
1. Front Cover
2. Feed Tube
3. Integral Damper
4. Water Panel
Evaporator Assembly
5. Distribution Tray
6. “V” Notches
7. Water Panel
8. Scale Control Insert
9. Drain Hose
MODEL 600