1. Note humidistat or control setting and turn dial to the “OFF” position.
2. Disconnect electrical power and turn off water supply.
3. Unlatch  humidifier  cover  assembly  (1)  from  base  assembly  (2)  at  the  bottom  of  the
cover, lift, and set aside.
4. Pull  out  the  water  panel  evaporator  assembly  (3)  by  grasping  at  the  top  and  tipping
out.
5. Remove the black distribution tray (4) from the water panel evaporator assembly (3) by
unsnapping the white plastic holding strips from the tabs at the end of the tray. Lightly
scrape out any calcium deposits and clean the “V” notches (5) but do not scrape off
the  granular  coating  from  the  bottom. 
This  textured  surface  helps  ensure  even
water flow for maximum performance. 
6. Slide the Water Panel evaporator (6) out from the white plastic Scale Control Insert (7).
Clean  the  Scale  Control  Insert by  twisting  and  flexing  it  to  loosen  the  calcium
deposits or use a putty knife. Inspect the Water Panel evaporator (Stock No. 35) and
replace with a new Genuine Aprilaire Water Panel if necessary. Slide the Water Panel
evaporator back into the scale control insert with the red colored spot up and snap the
black distribution tray (4) back into place.
7. Re-install the water panel evaporator assembly (3) into the base assembly (2). Push it in
at the top between the retaining ribs that hold the assembly in place in a vertical posi-
tion.
8. Remove the drain hose (8) from the bottom of the unit. Bend and flex it to loosen the
internal calcium deposits. Then flush it with water under pressure and slip it back onto
the drain fitting.
9. Reinstall  cover  assembly  (1)  by  hooking  at  the  top  of  the  base  assembly  (2)  and 
latching at the bottom.
10. Reconnect electrical power (9) and turn on the water supply.
11. Check system operation:
Humidifier Control: (Automatic or Manual) Check system operation by set-
ting the knob to “Test.” With furnace blower operating and furnace calling
for heat, humidifier will operate for one minute.
12. Set Humidifier or control to its original position.
MAINTENANCE INSTRUCTIONS
for
APRILAIRE HUMIDIFIER MODEL 700
WARNING!  120 volts may cause serious injury from electrical shock. Disconnect
power and shut off water supply before servicing.
1. Front Cover
2. Base
3. Water Panel Evaporator 
Assembly
4. Distribution Tray
5. ”V” Notches
6. Water Panel
7. Scale Control Insert
8. Drain Hose
9. Power Cord
MODEL 700