Programming
19
F232182
Test Cycle
1. Verify that the Run/Program Mode toggle switch 
is in the Run position.
2. Press the Up or Down key until the display 
alternately flashes “tESt” and “CYC,” indicating 
that the test cycle is selected.
3. Press the Start key to begin the test cycle.
NOTE: If “bAL?” or “SPC?” appear on display, 
ignore it; computer will proceed automatically.
NOTE: Pressing the Start key while the test cycle is 
in progress will immediately advance to the next 
step in the test cycle. Drain and load balancing 
steps may not
 be skipped.
The test cycle is as follows:
a. Once the Start key is pressed, the door 
interlock is de-energized (preventing the door 
from being opened), the drain valve closes, 
the cylinder begins agitating at wash speed, 
and both water inlet valves are energized. The 
display alternately flashes “bFIL” and “Lo” 
(both hot and cold fill valves on, filling to low 
level).
b. When the water level switch indicates that low 
water level has been reached, the water fill 
valves shut off and the dot above and to the 
immediate left of the fourth digit of the 
display lights.
c. The cold water fill valve is energized. The 
display alternately flashes “CFIL” and “
n
Ed” 
(cold fill valve on, filling to medium water 
level).
d. When the water level switch indicates that 
medium water level has been reached, the 
cold water fill valve shuts off and the dot 
above and to the immediate left of the third 
digit of the display lights.
e. The hot water fill valve is energized. The 
display alternately flashes “HFIL” and “HI” 
(hot fill valve on, filling to high water level). 
f. When the water level switch indicates that 
high water level has been reached, the hot 
water fill valve shuts off and the dot above 
and to the immediate left of the second digit 
of the display lights.
g. The auxiliary heat output is energized, 
provided that the water level switch indicates 
that at least low water level is present. The 
cold water fill valve is energized. The supply 
1 output is energized for five seconds. The 
display alternately flashes “SUP1” and 
“HEAt” (supply 1 output on, auxiliary heat 
output on).
h. The supply 2 output is energized for five 
seconds. The display alternately flashes 
“SUP2” and “HEAt” (supply 2 output on, 
auxiliary heat output on).
i. The supply 3 output is energized for five 
seconds. The display alternately flashes 
“SUP3” and “HEAt” (supply 3 output on, 
auxiliary heat output on).
j. The auxiliary heat output is turned off. The 
supply 4 output is energized for five seconds. 
The display shows “SUP4” (supply 4 output 
on).
k. The supply 5/auxiliary fill output energizes 
for five seconds. If the “SUP5”/“AFIL” setup 
option is set to “SUP5,” the display shows 
“SUP5” (supply 5/auxiliary fill output on). If 
the “SUP5”/“AFIL” setup option is set to 
“AFIL,” the display shows “AFIL” (supply 5/
auxiliary fill output on).
l. The cold water fill valve turns off. The 
recirculation pump output is energized for ten 
seconds, provided that the water level switch 
indicates that at least low water level is 
present. The display shows “PU
n
P” 
(recirculation pump output on).
m. The motor rotates counterclockwise (in 
reverse) at normal wash speed for 60 seconds. 
The display alternately flashes “SLo” and 
“rEv” (normal wash speed, 
counterclockwise).
n. The motor rotates clockwise (forward) at 
normal wash speed for 60 seconds. The 
display alternately flashes “SLo” and “For” 
(normal wash speed, clockwise).
o. The motor rotates counterclockwise (in 
reverse) at normal wash speed for 60 seconds. 
The display alternately flashes “nor
n
” and 
“rEv” (normal wash speed, 
counterclockwise).