12 
D: 
CONTROL AND AUXILIARY EQUIPMENT 
INSTALLATION OF A STANDARD WALL PUSH BUTTON OR DELUXE WALL STATION CONTROL 
 
A standard wall push button is included 
in your hardware package, an optional 
Deluxe Wall Station may be purchased 
from your installing dealer. The operat-
ing parameters for the standard wall 
push button and the Deluxe Wall Station 
are outlined on pages that follow 
(“Operating Instructions”) to see what 
mode of operation is right for you.  All-
star  recommends the Deluxe Wall Sta-
tion installation, as it will provide full 
control over the garage door operator and its functions at all times.  You may install one Deluxe Wall Station and one or more stan-
dard push buttons to a Challenger AC9000 Series operator following the cautions and instructions outlined below. 
 
STEP 1: 
 After determining a suitable location, usually near the access door and at least 5 feet above the floor to prevent use by 
children, use the standard wall push button or Deluxe Wall Station as a guide to mark the mounting holes.  Drill holes for drywall 
anchors or screws.  NOTE: Do not mount directly to masonry walls.  Use backer board. 
STEP 2:
  A length of 2-conductor, #22 gauge wire (or heavier) is required to connect the control button to the garage door operator.  
Strip approximately 2” of the wire jacket from one end and 1/2” of insulation from each wire.  Carefully connect one wire to each of 
the two terminals. Carefully tuck the loose wires into the case and mount the unit using appropriate screws. 
 
STEP 3: 
 Run the wire from the control button to the operator, supporting it at 18” intervals with suitable staples.  Leave a 
sufficient length to make the necessary connections to the operator terminal strip. 
 
WARNING:  SOME LOCAL BUILDING CODES DO NOT ALLOW 
SURFACE WIRING.  BE SAFE AND CHECK WITH YOUR LOCAL 
BUILDING INSPECTOR FIRST. 
STEP 4:
  Ensure power is OFF to the operator or disconnect the power from the 
operator.  Strip approximately 4” of jacket from the end of the wire and 1/2” 
insulation from each wire.  Connect to terminals 0 and 1 as shown in the 
illustration. Support the wire near the operator with wire ties. 
Step 5: 
Install the 
Co ntr ol B utto n 
W ar ni n g  L ab el 
supplied with your 
Challenger AC9000 
Series operator near 
the control button 
 
(see illustration). 
 
Repeat the Steps 1 
thru 5 above to in-
stall additional stan-
dard wall push but-
tons if desired. 
 
Every control must 
have a separate Con-
trol Button Warning 
Label mounted near it. Contact the factory for additional labels if 
needed. 
 
    
    
        
WARNING
WARNING
WARNING
WARNING    
A CHILD OPERATING THE DOOR CONTROLS 
RISKS INJURY — OR DEATH — TO HIMSELF AND 
OTHERS.  DO NOT ALLOW CHILDREN TO 
OPERATE 
ANY 
DOOR CONTROLS.   
MOUNT THE PUSHBUTTON AT LEAST 5 FT FROM 
THE FLOOR, OUT OF REACH OF CHILDREN. 
!!!!
Child can be pinned under automatic garage 
door. Death or serious injury can result.
•  Never let child walk or run under moving door.
•  Never let child use door opener controls.
•  Always keep moving door in sight.
•  If person is pinned, push control button or use 
emergency release.
•  Test door opener monthly:
Refer to your owner’s manual
Place one-inch object (or 2x4 laid flat) on floor.
If door fails to reverse on contact, adjust opener.
If opener still fails to reverse door, repair or replace opener.
WAR N I N G  
104350 
CONTROL BUTTON WARNING LABEL 
    
    
        
WARNING
WARNING
WARNING
WARNING    
IMPROPER DOOR OPERATION COULD 
CAUSE INJURY OR DEATH.  WARNING 
LABEL MUST BE MOUNTED ON WALL NEAR  
THE PUSHBUTTON.  ALL WARNINGS AND 
INSTRUCTIONS ON THE LABEL SHOULD BE 
STRICTLY ADHERED TO. 
109986