CONTROL AND AUXILIARY EQUIIPMENT 
SAFE FINISH™ PHOTOSYSTEM INSTALLATION 
 
 
Identify which side of the garage door opening (if any) the sun is “likely” to shine 
into.  As sunlight may cause undesirable operation, mount the sending unit (black 
button below the window) on the side of the door opening exposed most to the sun. 
 
STEP 1:  Mounting the Photosystem Wall Brackets 
  Select a 
mounting position 5 inches above the floor to the center line wall bracket.  The 
sending and receiving units should be mounted inside the door opening to minimize 
any interference by the sun.  However, the sensors should be mounted as close to 
the door track or inside edge of the door as possible to offer maximum entrapment 
protection.  The brackets may be temporarily 
mounted to the wall (or jamb) with the 1” flathead 
nail provided.  Leave this nail in place after 
installation of the lag screw below to prevent 
accidental rotation of the bracket  NOTE: It is very important that the wall brackets be mounted at 
exactly the same height so they will be aligned. 
 
Using the 1/4” x 1-1/2” lag screw provided, attach the wall bracket securely to the wall.  In some 
installations it may be necessary to attach wooden spacers to the wall to achieve the required 
clearance.  Expansion bolts (not supplied) may be required to attach brackets to walls constructed of 
materials other than wood or gypsum.  Repeat for the wall bracket on the other side of the door 
opening. 
 
STEP 2: Wire Connect the Photosystem 
 
Refer to page 20 for wiring diagrams of the Safe Finish™ Photosystem and garage door opener.  The following outlines the 
“PHOTOCELL SERIES CONNECTION (RECEIVER FIRST)” wiring diagram. 
A. Run a wire pair (not supplied) around the garage door jamb between the transmitter and receiver "L" mounting brackets.   
NOTE: Leave about 12” of extra wire at each end. Use a minimum 22 gauge solid "trace" wire (one wire in set should be 
marked to identify it at each end) for interconnect. 
B. Run a wire pair (20 or 22 gage solid wire) from the receiver position (unit with "LED" light in the front, may be either side of 
the door) back to the rear bulkhead of the garage door opener.  NOTE: Leave about 12” of extra wire at the receiver end and 
about 24” of extra wire at the opener end.  Use a minimum 22 gauge solid "trace" wire (one wire in set should be marked to 
identify it at each end) for interconnect. 
C. Strip approximately 5/16” from each wire end at the photosystem units and at the opener. 
D. Using two (2) wire nuts (supplied), connect the wire ends at the Safe Finish™ Photosystem transmitter to the pigtail wire ends 
coming out of the transmitter unit.  
Observe polarity, connect the trace wire ends (with black stripe) together and the 
unmarked wire ends together.  See wiring diagrams on page 20 .
 
Using two (2) wire nuts (supplied), connect the wire ends at the SAFE FINISH™ Photosystem receiver to the pigtail wire ends 
coming out of the receiver unit.  
Observe polarity, connect the trace wire ends (with black stripe) together and the 
unmarked wire ends together. 
 
STEP 3 Final Installation of Photosystem Units 
 
A. Attach the"U" brackets to the "L" brackets with a 1/4-20 carriage bolt, 
washer and hex nut (provided). Insert the bolt from the inside of the 
"U" bracket and hand tighten only at this time. 
B. Place the transmitter and receiver units into their respective "U" 
brackets.  NOTE: It is easier to slip the photosystem units in from the 
side of the bracket than forcing them in from the front of the bracket.  
See Illustration, at right. 
C. Connect the interconnect wire pair to the garage door opener terminals. 
Connect the trace wire (with black stripe) to the operator 
terminal marked 
“4”  and the solid color wire to the operator 
terminal marked 
“5”. See Wiring Diagrams on  page 20 .
 
104382 
104383 
1/4” x 1-1/2” 
Lag Screw 
5 Inches 
Above the Floor 
#8 Hex 
Head 
Screw 
12 Inches From Door Opening 
110052-1