Adjustment #3:  Setting Door Close Limit 
 
Confirm trolley close position 9” to 10” between the inside face of the door 
and the point where the door arm connects to the trolley (see illustration). 
 
If adjustment of the close trolley position is necessary, activate the opener and 
move the trolley 12” to 18” to provide access to the “Limit Stop” devices 
(mounted on the chain).  Move the limit stop to establish the correct trolley 
close position as above. 
 
Relocation of “Limit Stop” toward the door increases down travel.  
Relocation of the limit stop away from the door reduces down travel.  Note 
that each chain link provides 1/2” adjustment of trolley travel. 
Cushion Arm 
Assembly 
Trolley 
(Close Limit Position) 
Door 
Bracket 
9”to10” 
110054-1 
Chain 
Limit Stop 
 
Important Test: Opener Obstruction Sensing Feature for Doors (both Sectional and One Piece) 
 
A.  Activate door to the Open position. 
 
B.  Place 2” x 4” laid flat on garage floor under path 
of the door.  See Figure. 
 
C Activate door to close position; upon contacting 
solid object, the door should stop, then reverse 
direction within 2 seconds and travel to the full 
open position. 
 
Note:  If the fails to pass this test, see Adjustment 
3 above and move the Close Limit Stop one 
increment towards the door to increase down 
travel. Also review Steps 8 and 9, Page 10 for 
Sectional Doors or Step 10, Page 11 for One 
Piece Doors. 
 
REPEAT THIS TEST MONTHLY! 
Solid Test Object 
110055-3 
E:
 OPERATION AND ADJUSTMENT INSTRUCTIONS 
Adjustment #4:  Obstruction Sensing (Closing Direction) 
 
Your opener is designed to automatically reverse the door during closing travel 
whenever it comes into contact with an object up to the last 1-1/2 inch of travel 
above the floor.  An object on the floor with a height of less than 1-1/2 inch will 
cause the door to stop.  (Test according  to the instructions below.) 
 
If the opener reverses properly with a 2” x 4” laid flat on the garage floor (as the test 
below) and stops in the fully closed position, proceed to Adjustment #5. 
 
If the door reverses when it comes into contact with the floor, move the close limit 
stop, located on the left side (inside looking out, see figure Adjustment #1), towards 
the power head unit.  It is advised that you move the close limit stop one link at a 
time and run  opener through another close cycle, until the door stops when it comes 
into contact with the floor. 
 
When the door comes into contact with a 2” x 4” laid flat on the garage floor and stops intends of reversing, move the close limit stop 
away from the power head unit.  It is advised that you move the close limit stop one link at a time and run opener through another 
close cycle, until the door reverses when it comes into contact with the 2” x 4”. 
 
IF LIMITS ARE NOT ADJUSTED  
PROPERLY, THE EMERGENCY 
RELEASE MECHANISM MAY 
NOT WORK PROPERLY AND 
DOOR OPERATION COULD  
RESULT IN DOOR DAMAGE, 
SERIOUS PERSONAL INJURY 
OR DEATH!
 
WARNING
WARNING
WARNING
WARNING