Справочник Пользователя для Allstar Products Group AC9300

Скачать
Страница из 24
20 
SAFE FINISH PHOTOSYSTEM WIRING - SERIES AC9000 
 
MAINTENANCE OF YOUR OPENER 
 
Once a Month: 
 1.  Test for reversal on a 1-1/2 inch high object or a 2 x 4 board laid flat on the floor (see “Important Test: Opener 
Obstruction Sensing Feature”, page 18).  If  adjusting either the force or the limit of travel, retest the opener.  
Failure to adjust the opener may cause serious injury or death. 
 2.  Test for reversal with a 6 inch high by 12 inch wide object breaking the Safe Finish™ Photosystem beam (see 
“Important Test: Photoelectric Obstruction Test”, page 19). 
 3.  Manually operate the door (ensure door is in the closed position before attempting to engage manual operation, see 
 Cautions on page 16).  If it is unbalanced or binding, call a professional garage door service person. 
 4.  Check to be sure the door opens and closes fully.  Adjust limits or force of travel if necessary. 
 5.  Repeat safety reverse test (No. 1 above).  Make any necessary adjustments. 
 
Twice a Year: 
 1.  Check chain tension.  Adjust if necessary. 
 
Once a Year: 
 1.  Oil door rollers, bearings and hinges (silicone lubricant 
spray). 
SAFE FINISH WIRING DIAGRAM / MAINTENANCE SCHEDULE 
109985