Brookhaven Direct Vent Gas Fireplace
Top of Unit to Ceiling ................................32” (813 mm)
Front of Unit to Combustibles ...................36” (914 mm)
Appliance
 
Top of Standoff .........................................0” (0 mm)
 
Bottom ......................................................0” (0 mm)
 
Side .....................................................3/4” (19 mm)
 
Back .........................................................0” (0 mm)
Venting
Concentric sections of DV Vent ....................1” (25 mm)
Nonconcentric sections of DV Vent
 
Sides and Bottom ...................................1” (25 mm)
 
Top .........................................................2” (51 mm)
Clearance to Combustibles
Mantels
The height that a combustible mantel is fitted above the 
fireplace is dependent on the depth of the mantel. This 
also applies to the distance between the mantel leg (if 
fitted) and the fireplace.
For the correct mounting height and widths refer to 
Figs. 3a and  3b, and the following Mantel Charts.
The fitting of a bay window trim kit does not effect 
the distances and reference points referred to in the 
diagram and chart.
Noncombustible mantels and legs may be installed 
at any height and width around the appliance. When 
using paint or lacquer to finish the mantel, such paint or 
lacquer must be heat resistant to prevent discoloration.
CFM170
J
F
G
H
I
CFM164b
Mantel Leg Char
DVT44
4/9/03   djt
CFM170
DV Builder Front 
View
O
N
M
L
K
Side of Fireplace
CFM164b
 
 
Mantel 
 
Mantel Leg From Side
  Ref. 
Leg Depth 
Ref. 
of Comb. Opening
 
12  (305 mm)  K 
12” 
(305 mm)
 
9”  (229 mm) 
9” 
(229 mm)
 
6”  (152 mm)  M 
6” 
(152 mm)
 
4”  (102 mm)  N 
4” 
(102 mm)
 
3”  (76 mm) 
3” 
(76 mm)
Fig. 3b  Combustible mantel leg minimum installation.
A hearth is not mandatory but is recommended for  
aesthetic purposes.  We recommend a noncombustible 
hearth which projects out 12” (305 mm) or more from 
the front of the fireplace.
Cold climate installation recommendation:  
When installing this unit against a 
non-insulated exterior wall or chase, 
it is mandatory that the outer walls 
be insulated to conform to applicable 
insulation codes.  
Hearth
Proposition 65 Warning: Fuels used in gas, wood-
burning or oil fired appliances, and the products of 
combustion of such fuels, contain chemicals known to 
the State of California to cause cancer, birth defects 
and other reproductive harm.
California Health & Safety Code Sec. 25249.6
CFM146
A
B
C
D
E
V
W
X
Y
Z
Fireplace
CFM146
DV Mantel Chart
7/5/01   sta
Top of Combustion 
Chamber
Mantel Chart
Fig. 3a  Combustible mantel minimum installation.
Maintain minimum 2¹⁄₂” 
(64 mm) clearance to 
combustible
 
 
Mantel Shelf 
 
Mantel from Top of
  Ref. 
or Breast Plate 
Ref.  Combustion Chamber
 
 
Depth 
 
20DVT
 
10”   (254 mm) 
18¹⁄₂”  (470 mm)
 
8”   (203 mm) 
16¹⁄₂”  (419 mm)
 
6”   (152 mm) 
14¹⁄₂”  (368 mm)
 
4”   (101 mm) 
12¹⁄₂”  (318 mm)
 
2”   (51 mm) 
10¹⁄₂”  (267 mm)
Fireplace 
Front
Combustion 
Opening