LDVR Series Direct Vent Gas Fireplace
10007317
Ceramic refractory panels are available in kit form for 
the LDV series appliances
 
Appliance Model 
Kit Name
 
33LDVR 
33LDVRCR
 
36LDVR 
36LDVCR
 
39LDVR 
39LDVCR
 
43LDVR 
43LDVCR
Ceramic Refractory Kits
The fireplace, when installed, must be 
electrically connected and grounded in 
accordance with local codes or, in the 
absence of local codes, with the current 
CSA C22.1 Canadian Electric Code.
For USA installations follow the local codes 
and the national electrical code ANSI/NFPA 
No. 70.
Should this fan require servicing or repair 
the power supply must be disconnected. 
For rewiring of any replacement parts refer 
to Figure 55. 
Any electrical rewiring of this fan must be 
done by a licensed electrician.
 
Wiring Instructions
Black
White
Ground
FP394
WIRING DIAGRAM
11/20/96
Speed 
Control
Temperature Sen-
sor
Fan
FP1025
Fig. 55  FK24 fan wiring.
Take care when handling the refractory 
panels as they are fragile until held in place 
and supported.
Installation Refer to Figures 56 & 57
1.  Remove the front window frame assembly.
2.  Remove the logs.
3.  Place the rear refractory panel in place. Locate the 
lower edge of the panel in the ledge formed by the 
top of the rear log support bracket.
4.  Slide the side refractory panels into place to hold 
the rear panel secure. Repeat the procedure on the 
other side.
5.  Replace the logs and window frame assembly.
For aesthetic purposes we recommend aligning the 
horizontal mortar lines.
FP1231
Ceramic panels
11/02
Side 
Panel
Side 
Panel
Log Support
Burner Tray
Back Panel
FP1231
Fig. 56  Ceramic panel installation.
FP1232
rear ceramic panel
11/02
Rear Refrac-
tory Panel
Firebox Back 
Panel
Rear Panel 
Support 
Brackets
Rear Log 
Support
FP1232
Fig. 57  Rear refractory panel installation.
Remote Controls
Optional remote control units are available to control 
different functions of the appliances
 
Model 
Function/s Controlled
 
MRCI 
ON/OFF
 
MRC2 
ON/OFF and Temperature
 
MRC3 
ON/OFF and Temperature    
 
 
control with a digital display   
 
 
and programmable 24 hour clock
 
IMT 
Wall mounted thermostat control  
 
(must be used in bedroom installations)