Справочник Пользователя для Regency P40-NG1

Скачать
Страница из 56
Regency
®
 P40-1 Direct Vent Gas Fireplace
29
INST
ALLA
TION
INSTALLATION
CONVERSION KIT #502-966 FROM LP TO NG
NG Conversion Kit Contains:
Qty.   Part # 
 
Description
1  
    910-463  
NG Conversion Coil
1      910-036  
NG Pilot Orifi ce
1      904-644  
Orifi ce #35
1      904-568  
Orifi ce #44
1  
    910-249  
J9 Jumper
1      904-529  
Allen Key
1      908-514  
NG Conversion Decal
1      908-529  
NG Yellow Label
1      918-719  
Instruction Sheet
THIS CONVERSION MUST BE DONE BY A QUALIFIED GAS FITTER
IF IN DOUBT DO NOT DO THIS CONVERSION !!
1)
  Turn control knob to the OFF position; 
Shut off the gas supply to the valve; 
Unplug the power source.
2)
  Remove the louvers and the fl ush door.
3)
  Remove the logs.
4)
  Remove the Steel Fender, by loosening 
the retaining srews on both sides and slid-
ing it out of place.
5)
  Remove the front air box by undoing the 3 
screws.
6)
  Loosen the air shutter adjustment screw and 
pull out the air shutter adjustment wire.
7)
  Remove the 2 screws on the back burner.
8)
  Slide the burner to the right and lift out.
9)
  Remove the front burner by removing the 2 
screws. Lift the burner up and swing to the 
right and slide out.
10)
 Replace the rear burner orifi ce with #35, 
using a 1/2" wrench. See image below. 
Use another wrench to hold onto the elbow 
behind the orifi ce. 
11)
 Replace the front burner orifi ce with #44, 
using a 1/2" wrench. See image below. 
Use another wrench to hold onto the elbow 
behind the orifi ce. 
12) 
Remove the  pilot shield by removing the 2 
screws.
Pilot Shield
13)
 Remove the pilot head from the assembly 
using a fl at head screw driver to pop out.
Pilot Head
14)
  Remove the LP pilot orifi ce with the Allen Key 
and replace with NG pilot orifi ce. Reattach 
pilot head and clip.
Back Burner
Front Air Box
Air Shutter 
Adjustment Wire
Air Shutter 
Adjustment Screw
Rear Burner
Orifi ce
Front Burner
Orifi ce
Front Burner