Справочник Пользователя для Quadra-Fire CB1200I

Скачать
Страница из 52
February 3, 2010
7014-188B
Page  27
CB1200-I Pellet Insert
C.  Before Your First Fire
1.  First,  make  sure  your  appliance  has  been  properly 
installed and that all safety requirements have been met.  
Pay particular attention to the fire protection, venting and 
thermostat installation instructions.
2.  Double check that the ash pan and firebox are empty!
3.  Check the position of the thermocouple, located above 
the firepot, and make sure that it protrudes approximately 
3/4 inch (19mm) into the firepot.  
4.  Close the front door.  
D.  Starting Your First Fire
1.  A  thermostat  is  required  for  proper  operation  of  this 
appliance, except for corn.  At this time, fill the hopper 
with pellets, set the thermostat to its lowest setting.  Plug 
the power cord into nearby outlet.
2.  The  exhaust  blower  will  stay  on  for  approximately  10 
minutes  even  though  the  thermostat  is  not  calling  for 
heat.  This is normal.
3.  Locate the heat output control switch on the right side 
behind the right side panel.  Set to the HIGH setting and 
then  adjust  the  thermostat  to  its  highest  setting.    The 
red call light will be on which is located on the right side 
behind the right side panel.  This indicates the thermostat 
is calling for heat. Figure 27.1. 
4.  The fuel feed system and the igniter should now be on.
5.  For your first fire it will be necessary to press the reset 
button approximately 2 minutes after start-up and again 
at 4 minutes.  This will fill the feed system and allow the 
appliance to begin dropping pellets.  Continue pushing 
the reset button until you detect that pellets are being 
delivered into the firepot.  The appliance will continue to 
run as long as the thermostat is calling for heat.
6.  Once  the  appliance  has  ignited,  let  the  it  burn  for 
approximately 15 minutes, then set the thermostat to the 
desired room temperature.  Adjust the heat output control 
switch to the desired setting. 
 Odors and vapors released during initial operation.
•  Curing of high temperature paint.
•  Open windows for air circulation.
Odors may be irritating to sensitive individuals.
CAUTION
CAUTION
Tip of thermocouple must be in contact with the inside 
end of the thermocouple cover.
Missed ignitions can occur.
B.  General Operating Information
1.  Thermostat Calls For Heat
The appliance is like most modern furnaces; when the thermostat 
calls for heat, your appliance will automatically light and deliver 
heat.  When the room is up to temperature and the thermostat 
is satisfied, the red call light will shut off  and the appliance will 
shut down.  Figure 27.1.
2.  Heat Output Controls
Figure 27.1
Heat Output Switch
Reset Button
Red Call Light
Fuse
Control Box
Red / Green 
Light
Blue 
Blinking 
Light
This appliance is equipped with a heat output control switch that 
has three settings or burn rates; low, medium and high.  The 
appliance will turn on and off as the thermostat demands.  When 
the thermostat calls for heat, the appliance will always start up 
on High.  After burning approximately 4 minutes, the appliance 
will then burn at the rate at which it was originally set.  If the 
appliance is set at one of the lower settings, it will run quieter 
but takes longer to heat up an area than if it were set at a higher 
burn rate.  Regardless of the burn rate, when the area is warm 
enough to satisfy the thermostat, the appliance will shut off.
WARNING
Fire Hazard.
Keep combustible materials, gasoline 
and other flammable vapors and liquids 
clear of appliance.
•  Do NOT store flammable materials in the appliance’s 
vicinity.
•  DO NOT USE GASOLINE, LANTERN FUEL, KEROSENE, 
CHARCOAL LIGHTER FLUID OR SIMILAR LIQUIDS TO 
START OR “FRESHEN UP” A FIRE IN THIS HEATER. 
•  DO NOT BURN GARBAGE OR FLAMMABLE FLUIDS 
SUCH AS GASOLINE, NAPHTHA OR ENGINE OIL.
•  DO NOT USE CHEMICALS OF FLUIDS TO START THE 
FIRE. 
•  Keep all such liquids well away from the heater while it is in 
use.
•  Combustible materials may ignite.