Справочник Пользователя для Quadra-Fire CB1200I

Скачать
Страница из 52
Page  28
7014-188B
February 3, 2010
CB1200-I Pellet Insert
WARNING
Fire Risk
Do NOT operate appliance:
•  With appliance door open.
•  Firepot floor open.
•  Cleaning slide plates open.
Do NOT store fuel:
•  Closer than required clearances to com-
bustibles to appliance
•  Within space required for loading or ash 
removal.
Back side of Firepot
Firepot floor left open
Figure 28.1
 - DO NOT LEAVE FIREPOT FLOOR OPEN
E.  Fire Characteristics
A properly adjusted fire with the heat output control switch set 
on “HIGH” has a short active flame pattern that extends out 
of the firepot approximately 4 to 6 inches (102-105mm).  If 
the fire has tall flames with black tails and seems somewhat 
lazy, the feed rate will need to be reduced.  If the fire is not 4 
inches to 6 inches (102-105mm) tall, increase the feed rate.  
A medium and low setting will give a shorter flame.  The flame 
will rise and fall somewhat.  This is normal. 
The feed adjustment control rod is factory set, and should 
be adequate for most fuels.  The set screw is located at the 
bottom of the hopper and set loose at the factory so the fuel 
adjustment control rod will slide by only loosening the wing 
nut.  Do not re-tighten bottom set screw. 
However, if the flame height is too high or too low, you will 
F.  Feed Rate Adjustment Instructions
need to adjust the feed rate. Wait until the appliance has been 
burning for 15 minutes before making your adjustments and 
a
llow 15 minutes for feed adjustment to take effect.
  
1.  Open the hopper lid and locate the fuel adjustment control 
rod.
2.  Loosen the wing nut on the rod.  
3.  Adjust the fuel adjustment control rod towards the  "+"  
symbol  to  increase  the  feed  rate  and  flame  height  or 
towards the  "-"  symbol, to decrease the feed rate and 
flame  height.    Make  approximately  1/2  inch  (13mm) 
movements of rod at a time.
4.  Re-tighten the wing nut.
G.  Ignition Cycles
1.  During each ignition cycle, it is normal to see some smoke 
in the firebox.  The smoke will stop once the fire starts.
2.  The convection blower will automatically turn on after your 
appliance has reached the set temperature.  This blower 
transfers heat from your appliance into the room, and will 
continue to run after the thermostat has stopped calling 
for heat until the appliance has cooled down.
3.  Occasionally the appliance may run out of fuel and shut 
itself down.  When this happens, the red call light will be 
on.  To restart it, fill the hopper and press the reset button.    
When you press the reset button the red call light will go 
out.  Release the button and the light will come back on.  
You should see a fire shortly.  If not, follow the instructions  
“Starting Your First Fire”.on this page.