SAFETY
INFORMATION
Continued
15. Turn off and unplug heater and
     let cool before servicing. Only a
    qualified service person should
     service and repair heater.
16. Operating heater above elevations
    of 4,500 feet could cause pilot
     outage.
17. Do not operate heater if any log
      is broken. Do not operate heater
      if a log is chipped (dime-sized or
      larger).
18. To prevent performance problems,
     do not use fuel tank of less than
     100 lbs. capacity.
LOCAL  CODES
lnstall and use heater with care.
Follow all local codes. In the
absence of local codes, use the
latest  edition  of  The National  Fuel
Gas Code. ANSZ223.1, also   known
as  NFPA54*.
*Available from:
American  National  Standards
lnstitute,  lnc.
1430  Broadway
New  York. NY10018
National  Fire  Protection
Association,  lnc.
Batterymarch  Park
Quincy.  MA  02269
This  heater  is  designed  for  vent-
free operation. State and  local  codes
in some  areas prohibit the use of
vent-free  heaters.
UNPACKING
1.  Remove top inner pack.
2.  Tilt carton so that fireplace is upright.
3.   Remove protective side packaging.
4.  Slide fireplace out of carton.
5.  Remove protective plastic wrap.
6.   Remove two self-tapping screws
        o n   t h e   s c r e w   ,   t h e n   l i f t     a n d
pulling  forward.
7.  Remove log set by cutting plastic
ties.
8.  Carefully unwrap logs.
9.  Check for any shipping damage. If
    fireplace or logs are damaged,
     promptly inform dealer where you
     bought the fireplace from.
PRODUCT FEATURES
SAFETY PILOT
This  heater  has  a  pilot  with  an
Oxygen  Depletion Sensing (ODS)
safety  shutoff  system. The  ODS/
pilot is  a  required  feature  for  vent-
free room heaters. The ODS/pilot
shuts off the  heater  if  there  is  not
enough fresh  air.
PRODUCT   IDENTIFICATION
Figure1-Compact  Vent-Free  Fireplace
Water vapor is a by-product of gas combustion.An unvented room
heater productes approximately one (1) ounce (30ml) of wter for
every 1,000 BTU’s (.3KW’s) of gas input per hour.
Unvented room heaters are recommended as supplemental heat
(a room) rather than a primary heat source (an entire house) .In
most supplemental heat application, the water vapor does not
create a problem. In most applications, the water vapor enhances
the low humidity atmosphere experience during cold weather.
WATER VAPOR: A BY-PRODUCT OF UNVENTED ROOM HEATERS
The following steps will help insure that water vapor does not
become a problem.
1. Be sure the heater is sized properly for the application,
including ample combustion air and circulation air.
2. If  high humidity is experienced, a dehumidifier may be used
to help lower the water vapor content of the air.
3. Do not use an unvented room heater as the primary heat
source.
Remote control  SYSTEM
This fireplace has a remote transimit-
ter.This system requires three
batteries,  and  provides electric
power outlet to operate.
Mantel
Decorative 
Frame
Stove Cabinet
Screen
Log
Heater control