 NOTICE
:  This   heater   is
intended   for  use  as  supplemental
heat.  Use  this  heater along  with
your primary   heating  system.  Do
not   install   this  heater  as  your
primary heat   source.  If  you  have  a
central heating   system,   you   may
run system's   circulating  blower
while using  heater. This will help cir-
culate the  heat   throughout   the
house .
INSTALLATION
          WARNING:  A  qualified  service
person  must  install  heater. Follow
all  local  codes.
          WARNING:  Never install the
  heater:
 
in a  bedroom  or  bathroom
 
in a recreational vehicle
 
 where  curtains,  furniture,  clothing,
       or  other  flammable objects   are
      less  than  36  inches  from  the
       front, top, or sides  of  the  heater
 
in high traffic areas
 
in windy or drafty areas
           WARNING:   Maintain    the
minimum clearances.  If  you  can,
provide  greater  clearances  from
floor, ceiling, and adjoining  side and
back   walls.
         CAUTION:  This  heater  creates
warm air currents. These  currents
move  heat  to  wall  surfaces  next  to
heater. Installing heater next to  vinyl
or cloth wall coverings  or  operating
heater  where impurities (such as
tobacco  smoke, aromatic  candles,
cleaning  fluids, oil  or  kerosene
lamps, etc.) in  the  air  exist,may dis-
color walls.
IMPORTANT: Vent-free heaters add
moisture  to  the  air. Although  this  is
beneficial, installing heater in rooms
without enough ventilation air may
cause mildew. See Air for Combustion
and Ventilation
, pages 5 through 6.
CHECK  GAS  TYPE
Use  only  the type of  gas indicated on
the plate. If  your  gas supply  can not
meet that requirement, do not install
heater. Call dealer  where  you bought
heater  from  for  proper  heater  type.
Figure  4 -Minimum  Clearance  to  Wall
CLEARANCES TO COMBUSTIBLES
(Vent-Free  Operation  Only)
Carefully  follow  the  instructions  below.
This  fireplace  is  a  freestanding  unit
designed  to  set  directly  on  the  floor.
IMPORTANT:   You  must  maintain
minimum  wall  and  ceiling  clearances
during  installation. The  minimum
clearances  are  shown  in  Figure  4.
Measure from  outermost  point  of  fire-
place top.
Minimum Wall and Ceiling
Clearances
(see Figure 4)
A.   Clearances   from   outermost   point
of fireplace top to any combustible side
wall should not be less  than 12 inches.
B.   Clearances  from  the  fireplace top
to the ceiling should not be less than
48 inches.