SaFETy 
Continued
8.  Have venting system inspected annually by 
a qualified service person. If needed, have 
venting system cleaned or repaired. See 
Cleaning and Maintenance, page 30. 
9.  Do not use this fireplace to cook food or 
burn paper or other objects.
10. This appliance, when installed, must be 
electrically grounded in accordance with 
local  codes  or,  in  the  absence  of  local 
Figure 1 - Direct-Vent Fireplace with Millivolt Ignition
Glass Door Assembly
ON/OFF/REMOTE Switch 
(Optional Installation)
Log Set
Lava Rock
Glowing 
Embers
Upper Louver Panel
Lower Louver Panel
Flue Collar
Nailing Flange
Grate Assembly
Piezo Ignitor
Control Valve
Blower Switch (Optional Installation)
lOCal CODES
codes, with the National Electrical Code, 
ANSI/NFPA 70
.
11. Do not use fireplace if any part has been 
under water. Immediately call a qualified 
service person to arrange for replacement 
of the unit.
12. Do not operate fireplace if log is broken. 
13. Provide adequate clearances around air 
openings.
pRODUCT IDENTIFICaTION
Install and use fireplace with care. Follow all 
local  codes. In the absence  to local  codes, 
use the current National Fuel Gas Code ANSI 
Z223.1/NFPA 54*
.
*Available from:
American National Standards Institute, Inc.
1430 Broadway
New York, NY 10018
National Fire Protection Association, Inc.
Batterymarch Park
Quincy, MA 02269
pRODUCT FEaTURES
These are a few facts that can help you under-
stand and enjoy your direct-vent fireplace:
•  The venting system may be routed to the 
outside of your home in several ways. It may 
vent through the roof (vertical) or it may vent 
to an outside/exterior wall (horizontal). The 
vent  pipe  installation  is  very  important  to 
allow for proper operation. You must follow 
the  venting  instructions  very  carefully  for 
either vertical or horizontal applications.
•  This fireplace may be installed in any room 
of your house provided all local codes and 
these installation instructions are followed.
•  This fireplace does not require electricity 
to operate.
•  Only  the  blower  requires  electricity  if 
installed. If you plan to install the blower 
at a later date, outlet must be wired at the 
bottom of the fireplace when framing.
•  A piezo ignitor and ceramic electrode create 
sparks to ignite the pilot light. It does not 
require any matches, batteries or any other 
sources of ignition to light the pilot.
•  Each time you turn on your fireplace, you 
may notice some amount of condensation 
on  the  inside  of  the  fireplace  glass. This 
is  normal  and  will  disappear  after  10-20 
minutes of operation.
•  Your  direct-vent  gas  fireplace  system 
(fireplace and venting) is a balanced and