sealed gas operating unit. It requires ap-
proximately  10-20  minutes  of  operating 
time before the flame pattern stabilizes.
Figure 2 - Common Fireplace Locations
Flush with a wall
Through exterior wall 
enclosed in a chase
Corner 
installation
Figure 3 - Fireplace Bottom Dimensions
D
RW
FW
22 
1
/
2
"
34 
3
/
8
"
LOCATION AND SpACE REqUIREMENTS
Determine the safest and most efficient location 
for your FMI PRODUCTS, LLC direct-vent fire-
place. Make sure that rafters and wall studs are 
not in the way of the venting system. Choose a 
location where the heat output is not affected by 
drafts, air conditioning ducts, windows or doors. 
Figure  2  shows  some  common  locations.  Be 
aware of all restrictions and precautions before 
deciding the exact location for your fireplace and 
termination cap.
When deciding the location of your fireplace, 
follow these rules:
•  Do not connect this fireplace venting to a 
chimney flue serving a separate solid-fuel 
burning fireplace or appliance.
•  Due to high temperatures, do not locate this 
fireplace in high traffic areas, windy or drafty 
areas or near furniture or draperies.
•  Proper clearances must be maintained.
•  If your fireplace is to be installed directly on 
carpeting, vinyl tile or any combustible mate-
rial other than wood, it must be installed on a 
metal or wood panel extending the full width 
and depth of the fireplace. See Figure 3.
•  Your  fireplace  is  designed  to  be  used  in 
zero clearance installations. Wall or framing 
material can be placed directly against any 
exterior surface on the back, sides or top of 
your fireplace, except where standoff spacers 
are  integrally  attached.  If  standoff  spacers 
are attached to your fireplace, these spacers 
can be placed directly against wall or framing 
material. See framing details on page 6.
•  If you plan on installing a television or enter-
tainment center recessed above your fire-
place, it is recommended that you maintain a 
minimum 18" above top of louver opening.
•  When locating termination cap, it is impor-
tant  to  observe  the  minimum  clearances 
shown in Figure 7, page 7.
•  If recessing into a wall, you can avoid extra 
framing by positioning your fireplace against 
an already existing framing member.
•  Do not recess termination cap into a wall 
or siding.
•  You  may  paint  the  termination  cap  with 
450º F  heat-resistant  paint  to  coordinate 
with the exterior finish. 
•  There  must  not  be  any  obstruction  such 
as  bushes,  garden  sheds,  fences,  decks 
or utility buildings within 24" from the front 
16 
5
/
8
"
CLEARANCES
Minimum clearances to combustibles for the 
fireplace are as follows:
*Back and sides 
0"
Perpendicular walls 
6"
Floor 
0"
Ceiling to louver opening  
42"
Front 
36"
Top  
0"
Vent  
(See  venting  instructions  for 
specific venting clearances.)
Combustible material with a maximum thickness 
of 5/8" may be flush with top front of fireplace.
* For back and sides of fireplace, do not pack with 
insulation or other materials. 0" clearance to com-
bustible materials are for framing purpose only.
pRODUCT FEaTURES 
Continued
•  Fireplaces with the suffix of -HA have been 
designed  to  operate  at  altitudes  of  4000 
feet and above.
pRE-INSTallaTION pREpaRaTION
of the termination cap.
•  Do not locate termination cap where exces-
sive snow or ice build up may occur. Be sure 
to clear vent termination area after snow falls 
to  prevent  accidental  blockage  of  venting 
system. When using snow blowers, do not 
direct snow towards vent termination area.
•  For  horizontal  installations  above  2,000 
feet, it is recommended that a 12" extension 
pipe be added before starter elbow and a 
round horizontal termination be used (see 
High Altitude Installation, page 16).