Справочник Пользователя для Friedrich ZQ05B10

Скачать
Страница из 24
—3—
1. PREFACE 
This service manual provides various service information, including the mechanical and electrical parts, etc. 
This room air conditioner was manufactured and assembled under a strict quality control system. 
The refrigerant is charged at the factory. Be sure to read the safety precautions prior to servicing the unit. 
1.1 FEATURES
•  DESIGNED FOR COOLING ONLY 
•  POWERFUL AND INCREDIBLE COOLING
•  TOP-DOWN CHASSIS FOR THE SIMPLE INSTALLATION AND SERVICE
•  BUILT-IN ADJUSTABLE THERMOSTAT
•  WASHABLE ONE-TOUCH FILTER
•  COMPACT SIZE  
1.2 SPECIFICATIONS 
 
 
 
 
 
 
  
 
MODELS 
ITEMS 
COOLING CAPACITY (BTU/h) 5,100 6,500
POWER SUPPLY (Phase, V, Hz)
1ø, 115V, 60HZ
INPUT (W) 540 670
OPERATING CURRENT (AMP.) 5.0 6.1
REFRIGERANT CONTROL
CAPILLARY TUBE 
REFRIGERANT CHARGE (R-22) 325g (7.9 oz) 335g (11.8 oz)
INSIDE FAN
TURBO FAN 
OUTSIDE FAN
PROPELLER FAN WITH SLINGER RING
AIR DISCHARGE
2-WAY (RIGHT AND LEFT)
CHASSIS
TOP-DOWN
PROTECTOR 
TEMPERATURE CONTROL
THERMISTOR
FAN MOTOR 6 POLES, 16W 6 POLES, 27W
• OVERLOAD PROTECTOR FOR COMPRESSOR
• INTERNAL PROTECTOR FOR FAN MOTOR
ZQ05B10 ZQ07B10