Справочник Пользователя для Toshiba RAS-M13EKCVP-E

Скачать
Страница из 136
– 7 –
Unit model
Indoor
RAS-M10EKCVP-E, RAS-M13EKCVP-E, RAS-M16EKCVP-E
Outdoor
RAS-M14EACV-E
RAS-M18EACV-E
Cooling Capacity (kW)
4.0
5.2
Cooling Capacity range (kW)
1.4 - 4.5
1.4 - 6.2
Heating Capacity (kW)
Heating Capacity range (kW)
Power supply
220~240V-1Ph-50Hz / 220V-1Ph-60Hz
Electric 
charactaristics
Indoor
(220V/230V/
240V)
Unit model
RAS-M10EKCVP-E
RAS-M13EKCVP-E
RAS-M16EKCVP-E(*1)
Runnning Current (A)
0.15
0.15
0.15
Power Consumption (W)
30
30
30
Power factor (%)
91/87/83
91/87/83
91/87/83
Outdoor
(220V/230V/
240V)
Unit model
RAS-M14EACV-E
RAS-M18EACV-E
Operation mode
Cooling
Heating
Cooling
Heating
Running current      (A)
4.87/4.64/4.44
7.12/6.80/6.50
Power Consumption (W)
1020
1540
Power factor          (%)
95
98
Starting current (A)
5.17/4.94/4.74
7.42/7.10/6.80
COP(Cooling/Heating)
3.70/–
3.25/–
Operating noise 
dB(A)
Indoor 
(Cooling/Heat-
ing)
Unit model
RAS-M10EKCVP-E
RAS-M13EKCVP-E
RAS-M16EKCVP-E(*1)
High
42/–
43/–
45/–
Medium
33/–
34/–
36/–
Low
27/–
27/–
29/–
Outdoor
(Cooling/Heat-
ing)
Unit model
RAS-M14EACV-E
RAS-M18EACV-E
2 indoor units operating
46/–
48/–
Indoor unit
Unit model
RAS-M10EKCVP-E
RAS-M13EKCVP-E
RAS-M16EKCVP-E(*1)
Dimension 
(mm)
Hight
250
250
250
Width
790
790
790
Depth
215
215
215
Net weight (kg)
9
9
9
Fan motor output (W)
30
30
30
Air fl ow rate (m
3
/h)  (Cooling/Heating)
550/–
560/–
640/–
Outdoor unit
Unit model
RAS-M14EACV-E
RAS-M18EACV-E
Dimension 
(mm)
Hight
550
550
Width
780
780
Depth
290
290
Net weight (kg)
36
40
Compressor
Motor output (W)
750
1100
Type
Twin rotary type with DC-inverter variable speed control
Model
DA111A1F-20F1
DA130A1F-25F
Fan motor output (W)
43
43
Air fl ow rate (m
3
/h)
1820
2100
Type
Flare connection
Flare connection
Piping connec-
tion
Indoor unit
Unit model
RAS-M10EKCVP-E 
RAS-M13EKCVP-E
RAS-M16EKCVP-E (*1)
Liquid side
6.35
6.35
6.35
Gas side
9.52
9.52
12.7
Outdoor unit
Unit model
RAS-M14EACV-E
RAS-M18EACV-E
Liquid side/gas side
6.35 / 9.52
6.35 / 9.52
Maximum length (per unit) (m)
20
20
Maximum length (total) (m)
30
30
Maximum chargeless length(total) (m)
20
20
Maximum height difference (m)
10
10
Additional refrigerant
20g/m (pipe length 21m to 30m)
20g/m (pipe length 21m to 30m)
Name of refrigerant
R410A
R410A
Weight (kg)
0.90
1.20
Wiring connection
Power supply
3 Wires : includes earth
Interconnection
4 Wires : includes earth
Usable temperature range (
°
C)
Indoor (Cooling/Heating)
21 to 32/0 to 27
Outdoor (Cooling/Heating)
5 to 43/-10 to 24
Accessory
Indoor unit
Unit model
RAS-M10EKCVP-E
RAS-M13EKCVP-E
RAS-M16EKCVP-E(*1)
Installation plate
1
1
1
1
1
Wireless remote controller
1
Batteries
2
2
2
Remote control holder
1
1
1
Zeolite-plus filter
1
1
1
Plasma Pure filter
1
1
1
Remote controller 
holder mounting screw
2 (
3.1×16L)
2 (
3.1×16L)
2 (
3.1×16L)
Owner’s manual
1
1
1
Mounting screw
6 (
4×25L)
6 (
4×25L)
6 (
4×25L)
Installation manual
1
1
1
Outdoor unit
Unit model
RAS-M14EACV-E
RAS-M18EACV-E
Installation manual
1
1
Specifications
1
1
0
Drain nipple
0
Water-proof rubber cap
0
0
2-1-2 Specifications
Cooling-only  models
• (*1) The RAS-M16EKCVP-E cannot be used in combination with the RAS-M14EACV-E.
• For performance when each indoor unit is combined with other unit, refer to the separate table.
• The specifications may be subject to change without notice for purpose of improvement.