Справочник Пользователя для Toshiba RAS-M13EKCVP-E

Скачать
Страница из 136
– 9 –
<Cooling> RAS-M18EAV-E , RAS-M18EACV-E
Operation 
mode
Volts
Operation
Status
Operating indoor unit
Unit capacity (kW)
Capacity (kW)
Running current
Power Consumption
V
A
B
A
B
kW
A
W
Cooling
220
1 unit
10
2.7
2.7 (1.1 to 3.2)
3.03 (1.43 to 3.83)
600 (220 to 800)
13
3.7
3.7 (1.1 to 4.2)
5.10 (1.43 to 6.49)
1100 (220 to 1400)
16
4.5
4.5 (1.1 to 4.9)
6.96 (1.43 to 7.88)
1500 (220 to 1700)
2 units
10
10
2.55
2.55
5.1 (1.4 to 6.1)
7.19 (1.69 to 9.97)
1550 (260 to 2150)
13
10
2.85
2.35
5.2 (1.4 to 6.2)
7.42 (1.69 to 10.06)
1600 (260 to 2170)
13
13
2.60
2.60
5.2 (1.4 to 6.2)
7.42 (1.69 to 10.06)
1600 (260 to 2170)
16
10
3.25
1.95
5.2 (1.4 to 6.2)
7.42 (1.69 to 10.06)
1600 (260 to 2170)
230
1 unit
10
2.7
2.7 (1.1 to 3.2)
2.90 (1.37 to 3.66)
600 (220 to 800)
13
3.7
3.7 (1.1 to 4.2)
4.88 (1.37 to 6.21)
1100 (220 to 1400)
16
4.5
4.5 (1.1 to 4.9)
6.65 (1.37 to 7.54)
1500 (220 to 1700)
2 units
10
10
2.55
2.55
5.1 (1.4 to 6.1)
6.88 (1.61 to 9.54)
1550 (260 to 2150)
13
10
2.85
2.35
5.2 (1.4 to 6.2)
7.10 (1.61 to 9.63)
1600 (260 to 2170)
13
13
2.60
2.60
5.2 (1.4 to 6.2)
7.10 (1.61 to 9.63)
1600 (260 to 2170)
16
10
3.25
1.95
5.2 (1.4 to 6.2)
7.10 (1.61 to 9.63)
1600 (260 to 2170)
240
1 unit
10
2.7
2.7 (1.1 to 3.2)
2.78 (1.31 to 3.51)
600 (220 to 800)
13
3.7
3.7 (1.1 to 4.2)
4.68 (1.31 to 5.95)
1100 (220 to 1400)
16
4.5
4.5 (1.1 to 4.9)
6.38 (1.31 to 7.23)
1500 (220 to 1700)
2 units
10
10
2.55
2.55
5.1 (1.4 to 6.1)
6.59 (1.55 to 9.14)
1550 (260 to 2150)
13
10
2.85
2.35
5.2 (1.4 to 6.2)
6.80 (1.55 to 9.23)
1600 (260 to 2170)
13
13
2.60
2.60
5.2 (1.4 to 6.2)
6.80 (1.55 to 9.23)
1600 (260 to 2170)
16
10
3.25
1.95
5.2 (1.4 to 6.2)
6.80 (1.55 to 9.23)
1600 (260 to 2170)
<Heating>RAS-M18EAV-E
Operation 
mode
Volts
Operation
Status
Operating indoor unit
Unit capacity (kW)
Capacity (kW)
Running current
Power Consumption
V
A
B
A
B
kW
A
W
Heating
220
1 unit
10
-
4.0
-
4.0 (0.7 to 5.2)
5.57 (1.10 to 7.88)
1200 (170 to 1700)
13
-
5.0
-
5.0 (0.7 to 6.5)
8.35 (1.10 to 11.73)
1800 (170 to 2530)
16
-
5.5
-
5.5 (0.7 to 6.9)
8.81 (1.10 to 11.73)
1900 (170 to 2530) 
2 units
10
10
3.25
3.25
6.5 (0.9 to 8.2)
8.35 (1.30 to 11.09)
1800 (200 to 2390)
13
10
3.51
3.19
6.7 (0.9 to 8.5)
8.58 (1.30 to 11.36)
1850 (200 to 2450)
13
13
3.35
3.35
6.7 (0.9 to 8.5)
8.58 (1.30 to 11.36)
1850 (200 to 2450)
16
10
3.88
2.82
6.7 (0.9 to 8.5)
8.58 (1.30 to 11.36)
1850 (200 to 2450)
230
1 unit
10
-
4.0
-
4.0 (0.7 to 5.2)
5.32 (1.06 to 7.54)
1200 (170 to 1700)
13
-
5.0
-
5.0 (0.7 to 6.5)
7.99 (1.06 to 11.22)
1800 (170 to 2530)
16
-
5.5
-
5.5 (0.7 to 6.9)
8.43 (1.06 to 11.22)
1900 (170 to 2530) 
2 units
10
10
3.25
3.25
6.5 (0.9 to 8.2)
7.99 (1.24 to 10.60)
1800 (200 to 2390)
13
10
3.51
3.19
6.7 (0.9 to 8.5)
8.21 (1.24 to 10.87)
1850 (200 to 2450)
13
13
3.35
3.35
6.7 (0.9 to 8.5)
8.21 (1.24 to 10.87)
1850 (200 to 2450)
16
10
3.88
2.82
6.7 (0.9 to 8.5)
8.21 (1.24 to 10.87)
1850 (200 to 2450)
240
1 unit
10
-
4.0
-
4.0 (0.7 to 5.2)
5.10 (1.01 to 7.23)
1200 (170 to 1700)
13
-
5.0
-
5.0 (0.7 to 6.5)
7.65 (1.01 to 10.76)
1800 (170 to 2530)
16
-
5.5
-
5.5 (0.7 to 6.9)
8.08 (1.01 to 10.76)
1900 (170 to 2530)
2 units
10
10
3.25
3.25
6.5 (0.9 to 8.2)
7.65 (1.19 to 10.16)
1800 (200 to 2390)
13
10
3.51
3.19
6.7 (0.9 to 8.5)
7.87 (1.19 to 10.42)
1850 (200 to 2450)
13
13
3.35
3.35
6.7 (0.9 to 8.5)
7.87 (1.19 to 10.42)
1850 (200 to 2450)
16
10
3.88
2.82
6.7 (0.9 to 8.5)
7.87 (1.19 to 10.42)
1850 (200 to 2450)
The above specification values are those under the conditions
Cooling Indoor: DB/WB=27/19
°
C
Outdoor: DB=35
°
C
Heating Indoor: DB=20
°
C
Outdoor: DB/WB=7/6
°
C