Справочник Пользователя для Toshiba Air Conditioner

Скачать
Страница из 3
TOSHIBA INTERNATIONAL CORPORATION
INDEX
 
MDS-O-0001 
Industrial Division / Houston Motor Plant
 
SHEET NO.
 
1 of 3
 
 
ISSUED
 
01/24/96
 
Motor Operation Procedure
SUPERSEDES
 
NEW
 
 
REVISION
 
0
 
REFERENCE USE ONLY WHEN ISSUED BY MOTOR MKTG. 
WRITTEN BY
 
I. MARQUEZ 
 
APPROVED BY
 
J. Bugbee 
Motor Lubrication
 
 
Dist: Mktg. 
 QC 
 
1. SCOPE 
 
To give recommended guidelines for electric motor relubrication. 
 
2. START 
UP 
 
Toshiba motors are properly greased at the time of manufacture.  It is recommended that 
if a motor has been stored for a period of six months or more, it should be lubricated prior 
to starting (See Fig. 1) using a standard hand held grease gun. 
 
 
Fig.  1 
FRAME SIZE 
QUANTITY of PUMPS 
 
 
 
143 ~ 256 
 
284 ~ 405 
 
444 and Larger 
2 to 3 strokes 
 
4 to 5 strokes 
 
6 to 10 strokes 
 
 
 
 
 
It should be noted that grease leakage around the shaft hole could indicated over-
packing.  Excess grease should be purged out by operating the motor temporarily with 
the relief open. 
 
 
Lubrication of electric motors should be done as a part of a planned maintenance 
program. 
 
 
Before greasing, be sure fittings are clean and free from dirt.  Always relubricate using 
grease that is fresh and free from contamination. 
 
 
Toshiba motors may be equipped with an automatic grease relief fitting, grease plug or 
grease cover plate for the outlet. 
 
 
It should be noted that it may be necessary to remove an automatic type fitting due to 
hardening of grease.  Motors utilizing a grease plate may require the scraping out of old 
grease a minimum of once every two years. 
 
3. STANDARD 
SERVICE 
 
1. 
Select the proper service condition from Fig. 2. 
 
2. 
Select the frequency and volume from Fig. 3. 
 
3. 
Before greasing be sure fittings are clean and free from dirt.