Motor Operation Procedure
SUPERSEDES
 
NEW
 
 
3. 
STANDARD SERVICE (-cont.) 
 
5. 
Remove relief plug or plate and using a low pressure hand held grease gun, pump the required 
amount of grease. 
 
6. 
For Frames 143T to 365T allow motor to run for 20 to 30 minutes and for Frames 405T and 
larger allow motor to run for 30 to 60 minutes before replacing hardware. 
 
7. 
Grease may not relieve from drain.  Use volumes recommended to avoid overgreasing. 
 
 
Fig.  2 
SERVICE CONDITIONS 
 
 
Standard Duty 
Eight hours per day; 
Light to normal loading; 
Clean condition, free from dust. 
 
 
 
Severe Duty 
24 hours per day; 
Light to normal shock loading, vibration; 
Exposure to dirt or dusty conditions. 
 
 
 
Very Severe Duty 
24 hours per day; 
High ambient; 
Normal to high shock loading, vibration; 
Dusty conditions; 
Confined mounting conditions 
 
 
 
 
4. RECOMMENDED 
GREASES: 
 
Confirm if the motor nameplate has specified the grease used. 
 
Standard, Severe Duty and 841 motors greased at the factory will use: 
 Grease 
Name: 
  Chevron 
SRI 
 
Manufactured By: 
 
Chevron U.S.A., Inc. 
 
Operating Ambient Temp.: 
-30°C to 50°C 
 
 
5. 
RECOMMENDED GREASES for STANDARD APPLICATIONS 
 
 
Use the following greases listed for the given temperature range, unless otherwise shown by the motors 
grease nameplate: 
 
 
Operating Ambient Temp. -30°C to 50°C 
 
 
Chevron SRI 
Exxon Unirex #2 
Exxon Polyrex 
Shell Dolium R 
Polystar RB 2 
Chevron U.S.A., Inc. 
Exxon Corp. 
Exxon Corp. 