Справочник Пользователя для Toshiba RAS-10SAX

Скачать
Страница из 56
– 39 –
9-3-2. Power can not be Turned on after Replacing Indoor PC Board
<Checking Procedure>
9-3-3. Outdoor Unit does not Operate
RY01
C02
RY02 
Brown
N
L
Power 
terminal
block
T02
PC board
Blue
White
Black
1
2
Indoor 
terminal
block
To the paragraph of
“No Power turns on”.
Does the OPERATION 
lamp flash?
YES
NO
Connect the AC
Power supply
Return the wiring of the
power relay is returned to
the normal procedure.
Is it wired as shown
in Figure below?
YES
NO
Shut off the power supply 
from AC outlet once and 
turn it on after 5 seconds.
Does the OPERATION lamp flash?
Does the power turn on by 
pushing the [START/STOP] button 
of the remote control?
Is cable connection 
 between indoor and outdoor 
units correct?
Check items as following procedure 
in 9-3-4, 9-3-5, 9-3-6.
Replace the 
PC board.
See "Power can not be turned on".
Relays (RY01, RY02)
or IC31 or IC30 is failure.
Correct cabling between 
indoor and outdoor units.
NO
NO
NO
NO
YES
YES
YES
YES
See "Power can not be turned on".
Is AC220/230/240V 
supplied between terminal block 
1  -  2  ?