9-3-4. Only Compressor does not Operate
Shut off the power supply 
from AC outlet once and 
turn it on after 5 seconds.
Does the OPERATION lamp flash?
Does the power turn on by 
pushing the [START/STOP] button 
of the remote control?
Is cable connection between indoor 
and outdoor units correct?
Replace the 
PC board.
See "Power can not be turned on".
NO
NO
NO
NO
YES
YES
YES
YES
Is the voltage across the outdoor terminal
 ( 1  -  2 ) 220/230/240 VAC?
YES
Are all the cords for compressor normal?
Is the compressor motor winding normal? 
(Check the winding resistor.)
Is the capacitor for compressor normal?
Is the overload relay normal?
Does the compressor start?
Compressor starts but 
it stops after a while?
Cables between indoor and 
outdoor units are defective.
Re-wire or replace the defective cords.
Compressor is defective.
Capacitor is defective.
Overload relay is defective.
Compressor is defective.
Correct cabling between indoor 
and outdoor units.
NO
NO
NO
NO
NO
NO
YES
YES
YES
YES
YES
YES
See "Power can not be turned on".
YES
Is the gas quantity normal?
(Check the pressure)
Gas shortage (Gas leakage)
NO
Compressor is defective
Is the voltage across the indoor terminal
 ( 1  -  2 ) 220/230/240 VAC?
Relays (RY01, RY02)
or IC31 or IC30 is failure.