Справочник Пользователя для Toshiba RAS-10SAX

Скачать
Страница из 56
– 42 –
9-3-6. Only the Indoor Fan does not Operate
< Check procedure >
YES
NO
Replace the 
PC board.
Shut off the power 
supply once.
Does the fan 
stop in no operating 
status?
Control PC board is defective.
Replace the PC board.
Start the operation 
with low fan setting 
in cool operation.
Does the fan rotate?
Change the setting of 
cooling to high fan.
Does the fan speed 
become higher?
Operation 
stops
Normal
Is the voltage 
measured DC35V 
  between  
1
  (red lead wire, +) 
  and  
2
  (black lead wire, –) 
of the motor connector 
(CN10) ?
Shut off the power supply.
Does the cross 
flow fan rotate 
normally?
Repair the 
bearing of 
the drain fan.
Turn on the power supply.
Is the rotation signal 
(DC+5V-0V) output between  
4
 
(blue lead wire) and  
2
  (black 
lead wire) of the motor connector 
(CN10) when rotating the cross 
flow fan by hand in no operating 
status ? (2 pulses/one turn)
Replace the control 
PC board.
Shut off the power supply,
and turn it on after 
disconnecting the motor 
connector (CN10)
from 
the PC board.
Is the voltage of 
DC35V measured  
between 1 (red lead wire, +)
 and 2 (black lead wire, –) of 
the motor connector 
(CN10) ?
Replace the 
fan motor.
YES
NO
YES
NO
YES
NO
YES
NO
YES
NO
YES
NO
Turn the power supply.
*