APPLICATION INSTRUCTIONS
 
 
 
 
 
 
 
 
 
 
 
 
 
S-2299
APPLICATION INSTRUCTIONS FOR TOTAL CONCEPT CLEANING OF BOILER
SIZE: 1 Gallon  PART NUMBER: 20 - 0307
GENERAL NOTES:
Market Forge R has two basic types of boilers; one has 
an automatic drain valve, the other has a manual drain 
valve. To determine which type you have, open cabinet 
doors and you will see a control box with two switches 
and an indicator light. The instruction label on the control 
box will identify the boiler as being either automatic or 
manual.  Those  boilers  designated  as  being  automatic 
must be energized in order to close the drain valve.
Total Concept is designed to be used with water between 
160°F to 200°F.
Preheating  is  required  on  both  automatic  and  manual 
boilers to raise the water temperature to the acceptable 
range. (160°F to 200°F).
For manual boilers, make certain drain valve is tightly 
closed.
On Market Forged boilers manufactured after 8/84; your 
unit is equipped with an access plug in the steam header 
line. This location should be used to add cleaner/des-
caler to boiler chamber during maintenance.
On Market Forged boilers manufactured before 8/84; ac-
cess to boiler chamber should be gained through either 
the vent-rite or the pressure relief valve.
Total Concept is a NSF listed nonfood product. This is 
a  liquid  acid  (nonmuriatic)  product  that  works  without 
fumes, odors, and hazards associated with other harsh 
chemicals.
BOILER TREATMENT CLEANING INSTRUCTIONS:
After  determining  proper  location  for  cleaner/descaler 
to be added: Read complete instructions thoroughly; in-
cluding all warning and cautionary statements.
 
  Fig. 1
1. Energize boiler and fill to operating level.
 
  Fig. 2
2. Energize heating circuit to pre-heat unit.
 
  Fig. 3
 
  Fig. 4
3. AUTOMATIC - After unit is pre-heated, cycle the pow-
er switch to the OFF position then immediately back 
to the ON position.