Справочник Пользователя для Market Forge Industries M36G100A-4SP

Скачать
Страница из 26
23
APPLICATION INSTRUCTIONS
 
 
 
 
 
 
 
 
 
 
 
 
 
S-2299
APPLICATION INSTRUCTIONS FOR TOTAL CONCEPT CLEANING OF BOILER
SIZE: 1 Gallon  PART NUMBER: 20 - 0307
 
  Fig. 5
4. Remove the shipping cap, replace it with the pouring 
cap. Cut the tip of the pouring cap at the first notch to 
a 45
o
 angle.
5. Install the tubing firmly over the tip of the  pouring 
cap.
 
  Fig. 6
6. Energize compartment to release steam pressure in 
boiler  to “0” PSI before removing pipe plug.
7. Remove the plug from the access port on the steam 
header pipe inside cabinet doors.
CAUTION:  HE7DER PIPE & ACCESS PLUG ARE HOT.
 
Fig. 7
 
Fig. 8
8. Feed the tubing through the access port in the boiler 
compartment.
NOTE: A minimum of 12” must be inserted.
 
Fig. 9
Tilt the container, pour the contents into the unit.
When empty, refill the container with hot tap water 
and  add  to  boiler  for  cleaning.  Repeat  twice. This 
additional 2 gallons of water will cause the low water 
probe to be immersed in cleaner/descaler solution. 
Replace access plug.
After  rinsing  the  container,  place  tubing  inside  the 
bottle, cover with shipping cap, dispose of properly. 
DO NOT REUSE CONTAINER.
DO NOT ENERGIZE HEATERS.  Allow 2 hours for 
cleaning.
After time has elapsed, drain the boiler.
Refill the boiler and drain. Repeat this step twice.
Bring the boiler to temperature and cycle steam to 
the cooker compartment to purge cleaner/descaler 
from the steam supply lines. Repeat this step twice.
Boiler is now ready for use.
9.
10.
11.
12.
13.
14.
15.