TROUBLESHOOTING
Continued
OBSERVED  PROBLEM
POSSIBLE CAUSE
REMEDY
Delayed   ignition  burner.
1.   Manifold  pressure  is  too  low.
2.   Burner orifice is clogged.
1.   Contact   local  gas company.
2.  Clean  burner (see Cleaning  and
       Maintenance, 
pages 11).
Burner  backfiring  during  combustion.
1.   Damaged  burner.
2.   Gas  regulator  is  defective.
1.   Clean  burner  orifice  (see  Cleaning
       and  Maintenance, page 11).
2.   Replace  gas  regulator.
Slight   smoke   or   odor   during  initial
operation.
1.   Residues  from  manufacturing
       processes.
2.   Not enough air.
3.   Gas  regulator is defective.
1.    Problem  will stop after a few hours
       of operation.
2.   Check  burner  for  dirt  and  debris.
       If  found, clean  burner (see Cleaning
       and  Maintenance, pages 11).
3.    Replace  gas  regulator.
Dark  residue  on logs  or  inside  of
fireplace.
1.   Improper  log  placement.
2.   Air holes at burner inlet are blocked.
3.   Burner flame holes are blocked.
1.  Properly locate logs (see Installing
Logs,  page  9).
2.   Clean out air holes at burner inlet.
Periodically  repeat  as  needed.
3.   Remove blockage or replace burner.
Heater  produces  a   clicking/ticking
noise  just  after  burner  is  lit  or  shut off.
1. Metal expanding while heating or
     contracting  while  cooling.
1.  This    is    common    with    most
    heaters. If  noise  is  excessive,
    contact  qualified service person.
Btu                                                             20000/25000                               20000/25000
Gas
 Type
                                                       LP Gas                                      Natural Gas
Ignition                                                            Piezo                                           Piezo
Manifold   Pressure                                          8"W.C.                                         3"W.C.
Inlet  Gas  Pressure
(In. of water)*
       Maximum                                                   14"                                             10.5"
       Minimum                                                    11"                                                5"
Dimensions, Inches (H×W×D)
       Heater                                               33 9/16”×23 1/8”×13 9/16”           33 9/16”×23 1/8”×13 9/16”
       Carton                                                36 7/8”×26 1/8”×16 1/2”              36 7/8”×26 1/8”×16 1/2”
Weight, lbs
       Heater                                                         73                                               73
       Shipping                                                      84                                               84
*For purposes of input adjustment
  SL250TYLA-D
     SN250TYLA-D
SPECIFICATIONS