Справочник Пользователя для Procom SL250TYLA-D

Скачать
Страница из 21
   9
         WARNING:   Failure  to  position
the  parts  in  accordance  with  these
diagrams may  result  in  property  dam-
age  or  personal  injury.
         CAUTION:    After  installation
and  periodically  thereafter,  check  to
ensure  that  no  flame  comes  in
contact   with  any  log.  With  the  heater
set  to  HIGH, check  to  see  if  flames
contact  any  log. If  so, reposition  logs
according  to the log  installation
instructions  in  this  manual. Flames
contacting  logs  will  create  soot.
INSTALLING  LOGS
Figure  10 -Installing  One-Piece  Log
Set (Top View)
INSTALLATION
Continued
IMPORTANTMake  sure  log  does not
cover any burner ports (see Figure10).
OPERATING    HEATER
FOR   YOUR   SAFETY 
READ   BEFORE
LIGHTING
                 WARNING:   If  you  do not
follow  these  instructions  exactly, a fire
or  explosion  may  result  causing prop-
erty  damage, personal injury or
loss  of  life.
         NOTICE:   During   initial  operation
of  new  heater,  burning logs  will  give  off
a  paper-burning smell. An orange  flame
will  also  be present. Open a  window  to
vent  the smell. This  will  only  last  a  few
hours.
         CAUTION:  Do not  try  to adjust
h e a t i n g     l e v e l s     b y     u s i n g     t h e
equipment  shutoff  valve.
Figure  12 -Pilot
A. This appliance has a pilot which must
be lighted by hand. When lighting the pilot,
follow these instructions exactly.
B. BEFORE LIGHTING smell all around
the appliance area for gas. Be sure to
smell next to the floor because some gas
is heavier than air and will settle on the
floor.
     WHAT TO DO IF YOU  SMELL GAS
     * Do not try to light any appliance.
     * Do not touch any electrical switch.
    * Do not use any  phone in your building.
     * Immediately call your gas supier from
a neighbor’s phone. Follow the gas
supplier’s instructions.
     * If you cannot reach your gas supplier,
call the fire department.
C. Use only your hand to push in or turn
the gas control knob. Never use tools. If
the knob will not push in or turn by hand,
don;t try to repair it; call a qualified service
technician. Force or attempted repair may
result in a fire or explosion.
D. Do not use this appliance if any part has
been under water. Immediately call a
qualified service technician to inspect the
appliance and to replace any part of the
control system and any gas control which
has been under water.
LIGHTING INSTRUCTIONS
1. STOP! Read the safety informatuion
above.
2. Set thermostat (gas control knob) to lowest
setting.
3. Turn off all electric power to the appliance
(if applicable).
4. Push in gas control knob slightly and turn
clockwise to “OFF”. Do not force.
5. Waitten (10) minutes to clear out any gas.
Then smell for gas, including near the floor.
If you smell gas, STOP! Follow “B” in the
safety information above. If you don’t smell
gas, go to the next step.
6. Find pilot-the pilot is attached at the
bottom of the burner assembly.
7. Turn gas control knob counterclockwise
to “PILOT”.
8. Push in gas control knob all the way and
hold in. Repeatedly push the pieze ignitor
button until pilot is lit (or use a match to light
pilot). Continue to hold the control knob in
for about one (1) minute after the pilot is lit.
Pilot should remain lit. If it goes out, repeat
steps 4 through 8.
     * If knob does not pop up when released,
stop and immediantely call your service
technician or gas supplier.
     * If pilot will not stay lit after several tries,
turn the gas control knob to “OFF” and call
your service technician or gas supplier.
9. Attention! Gas control has an interlock
latching device. When the pilot is intially lit
and the safety magnet is energized (pilot
stays “ON”) the INTERLOCK latching device
becomes operative. If the gas control is
turned to the “OFF” position or gas flow to
the appliance is shut off, the pilot cannot be
relighted until the safety magnet is de-
energized (approximately 60 seconds).
There will be an audile “click” when the safety
magnet in the gas control is de-energized.
Pilot can now be relighted. Repeat steps 4
through 8.
10. Turn gas control knob counterclockwise
to “HI”.
11. Turn on all electric power to appliance (if
applicable).
12. Set thermostat (gas control knob) to
desired setting from “HI” to “LO”.
TO TURN OFF GAS TO APPLIANCE
1. Set thermostat (gas control knob) to
lowest setting.
2. Turn off all electric power to appliance if
service is to be performed (if applicale).
3. Push in  gas control knob slightly and turn
clockwise to “OFF”. Do not force.
Figure  11 -Control Knob and
Ignitor Button location