Raising the Mast
Once  the  tower  mast  has  been  locked  into  its  vertical 
position, the mast can now be raised. The tower allows the 
lamps to be extended upwards in excess of 30 feet.
Refer to Figure 7 for location of components.
1.  Turn the mast extension winch clockwise and observe 
that the mast begins to extend upwards.
2.  Continue turning the winch in the clockwise direction 
until the desired height has been reached.
3.  Release the winch. This winch is of the self-locking 
type. The tension on the cable will keep the mast in 
place.
Lowering the Mast
1.  Turn the mast extension winch counterclockwise, and 
observe that the mast begins to lower.
2.  Continue turning the winch counterclockwise until the  
mast has been fully retracted (slack in the cable).
stowing the Mast to Horizontal position
Refer to Figure 7 for the location of components:
1.  Remove the mast lock/release pin to allow the mast 
section to be lowered to the horizontal position. Pull 
out the mast lock handle to unlatch.
2.  Turn  the  vertical  mast  winch  counterclockwise  and 
observe that mast begins to approach the horizontal 
position. The mast lock handle can now be released.
3.  Continue  turning  the  vertical  mast  winch  in  the 
counterclockwise direction. As the mast approaches 
the  mast  cradle  support,  pull  the  retaining  pin  and 
then the cradle lock/release pin to allow the mast to 
rest in the cradle.
4.  Once the mast is resting in the mast cradle support, 
insert  the  cradle  lock/release  pin  and  secure  with 
retaining pin to keep mast in place.
Rotating the Mast
To change the direction that the lamps are facing, the mast 
can be rotated.
Refer to Figure 7 for the location of components.
1.  With  the  mast  in  the  deployed  position  (vertical), 
unscrew the mast rotation locking knob to release the 
mast for rotation.
2.  Grip the mast rotation handles and rotate the mast until 
the lamps are facing the desired direction.
3.  When  the  lamps  are  facing  the  desired  direction, 
tighten the mast rotation lock knob to lock the mast 
in place.
TuRnIng On THe LaMps
Lamp circuit breakers (15 amps each) are located on the 
front of the light tower to turn the lamps on and off. See 
Table 3.
 
1.  Before turning on the lamps, make sure that main circuit 
breaker on the generator control panel and the circuit 
breakers shown in Figure 8 are all in the off position.
Figure 8. Lamp Circuit Breakers
Table 3. Lamp settings
Circuit Breaker (On)
Lamps (On)
CB1 
1
CB2
2
CB3
3
CB4
4
CB5
5
CB6
6
 NOTICE
Model  MLT20DCA  has  only  4  lamps  and  4  circuit 
breakers.
CB1
CB2
CB3
CB4
CB5
CB6