Справочник Пользователя для Multi Tech Equipment MLT20DCA

Скачать
Страница из 52
MLT20 seRIes LIgHT TOWeR • OpeRaTIOn ManuaL — Rev. #0 (01/18/13) — page 21
2.  Adjust the Voltage Regulator Knob to 120VAC. Check 
the AC voltmeter for the correct reading. See Figure 9.
Figure 9. Voltage Regulator Knob and AC 
Voltmeter
3.  Switch  the  appropriate  circuit  breakers  to  the  ON 
position for the lamps (Figure 10) that you want to turn 
on as detailed in Table 3.
Figure 10. Lamp Orientation (MLTDCA6)
DECREASE
INCREASE
AC Voltmeter
Voltage Regulator
LAMP 1
LAMP 2
LAMP 3
LAMP 4
LAMP 5
LAMP 6
REAR
FRONT
MAST RAISED
OperatiOn
4.  When  the  lamps  turn  on,  check  the  AC  voltmeter 
reading  and  adjust  the Voltage  Regulator  knob,  if 
necessary, to correct the voltage.
5.  If any of the lamps do not turn on as they should, refer 
to the troubleshooting section of this manual.
6.  Close all cabinet doors after desired lights are on.
 NOTICE
neveR  operate  the  light  tower  with  the  engine 
compartment  doors  open.  Operation  with  the  doors 
open may cause insufficient cooling to the unit, and 
damage may result.