storage capacities
table 2
moDEL
U. S. GALLoNS LITERS
SUF 60 120
60
227
SUF 100 150
100
379
SUF 100 199
100
379
SUF 100 250
100
379
gas line connection siZe
table 1
† moDEL
SERIES NATURAL GAS PRoPANE GAS
SUF 60 120
100/101 3/4 "NPT
3/4 "NPT
SUF 100 150
100/101 3/4 "NPT
3/4 "NPT
SUF 100 199
100/101 3/4 "NPT
3/4 "NPT
SUF 100 250
100/101 3/4 "NPT
3/4 "NPT
† Depending on the installed equivalent length, and/or the number of appliances 
connected, the supply gas line size may have to be increased beyond the 
minimum required sizes - see Gas Line Sizing on page 39.
table 3
u. s. gallons/hr & litters/hr at temperature rise indicated
model
Type of
Gas
Input
°F
30°F
40°F
50°F
60°F
70°F
80°F
90°F
100°F
110°F
120°F
130°F
140°F
btu/hr
kW
°C
17°C
22°C
28°C
33°C
39°C
44°C
50°C
56°C
61°C
67°C
72°C
78°C
SUF 60 120
Natural
120,000
35
GPH
461
345
276
230
197
173
154
138
126
115
106
99
Propane
LPH
1744
1308
1046
872
747
654
581
523
476
436
402
374
SUF 100 150
Natural
150,000
44
GPH
576
432
345
288
247
216
192
173
157
144
133
123
Propane
LPH
2179
1635
1308
1090
934
817
726
654
594
545
503
467
SUF 100 199
Natural
199,900
58
GPH
767
575
460
384
329
288
256
230
209
192
177
164
Propane
LPH
2904
2178
1743
1452
1245
1089
968
871
792
726
670
622
SUF 100 250
Natural
250,000
73
GPH
960
720
576
480
411
360
320
288
262
240
221
206
Propane
LPH
3632
2724
2179
1816
1557
1362
1211
1090
991
908
838
778
recovery capacities are based on 95% thermal efficiency.
recoVery capacities
8.  Locate the water heater where an adequate supply of fresh 
air for combustion and ventilation can be obtained. See Air 
9.  Locate the water heater where the vent and intake air piping, 
when  installed,  will  remain  within  the  maximum  equivalent 
10. Do  not  locate  the  water  heater  where  noise  (such  as 
the  Combustion  Blower)  during  normal  operation  will  be 
objectionable in adjacent areas.
11. Do  not  locate  the  water  heater  where  the  subsequent 
installation  of  the  vent  (exhaust)  or  intake  air  terminations 
would  be  objectionable  due  to  noise  at  the  termination(s). 
This includes locations close to or across from windows and 
Fire or Explosion Hazard
Read instruction manual before
installing, using or servicing
water heater.
Avoid all ignition sources if you smell gas.
Do not store or use gasoline or other flammable vapors and
liquids in the vicinity of this or any other appliance.
Use only the gas shown on the water heater rating label.
Keep ignition sources away from faucets after extended
periods of non-use.
Maintain required clearances to combustibles.
Do not expose water heater controls to excessive gas
pressure.
locating the water heater
Carefully  choose  a  location  for  the  new  water  heater.  The 
placement is a very important consideration for the safety of the 
occupants in the building and for the most economical use of the 
appliance. 
Property Damage Hazard
All water heaters eventually leak.
Do not install without adequate drainage.
CAUTION
Whether replacing an existing water heater or installing the water 
heater in a new location observe the following critical points:
1.  The water heater must be located indoors.
2.  The water heater must not be located in an area where it will 
be subject to freezing temperatures.
3.  Locate the water heater so it is protected and not subject to 
physical damage by a moving vehicle.
4.  Locate the water heater on a level surface.
5.  Locate the water heater near a floor drain. The water heater 
should be located in an area where leakage of the tank or 
connections  will  not  result  in  damage  to  the  area  adjacent 
to the water heater or to lower floors of the structure. When 
such locations cannot be avoided, it is recommended that a 
metal drain pan, adequately drained, be installed under the 
appliance.
6.  Locate the water heater close to the point of major hot water 
usage.
7.  Locate the water heater close to a 120 VAC power supply.