user Input buttons
•  The  up  and  down  buttons  are  used  to  navigate  menus  and 
adjust user settings.
 
•  The  operational  buttons  are  used  to  enter/exit  menus,  select 
menu items, activate adjustment modes and confirm or cancel 
new user settings. The operational buttons are multifunctional, 
their current function is defined by the text that appears directly 
above each button on the LCD screen. 
the desKtop screen
During  normal  operation  the  control  system  will  display  the 
"Desktop"  screen  on  the  LCD  which  is  the  default  screen.  The 
control  system  will  return  to  the  Desktop  screen  when  there  are 
no active Fault or Alert conditions or when there has been no user 
input for several minutes.
•  Manufacturer and water heater model information is displayed 
in Title Bar at the top of the Desktop screen. Menu titles are 
displayed in the Title Bar when navigating the control system 
menus.
•  The  first  temperature  shown  on  the  Desktop  screen,  Tank 
Temperature, is the temperature of the water inside the water 
heater's storage tank - commercial models only.
•  The Operating Set Point is also shown on the Desktop screen. 
The Operating Set Point is the temperature at which the control 
system will maintain the water inside the storage tank.
•  Beneath the Operating Set Point is the "Status" line. The Status 
line shows the current operational state of the control system in 
real time. See Table 4 for a description of the various operating 
states.
•  The Desktop screen also displays animated "Status Icons" to 
convey operational information, see Table 3 for a complete list 
and description of the Status Icons.
overvIew
The  water  heaters  covered  in  this  manual  are  equipped  with  an 
electronic control system that regulates water temperature inside 
the storage tank. Heating cycles and ignition are managed by the 
control system. The ECO (energy cut out), Flame Sensor, pressure 
switches  and  Temperature  Probe  is  monitored  by  the  control 
system. The Combustion Blower, Igniter and the 24 Volt Gas Valve 
are all energized by the control system.
The  main  components  of  the  control  system  are  a  UIM  (user 
interface  module)  and  a  CCB  (central  control  board).  The  UIM 
is  located  on  the  top  front  side  of  the  water  heater. The  CCB  is 
mounted on top of the water heater inside a protective enclosure.
coMMercIal and resIdentIal Models
The  water  heaters  covered  by  this  manual  are  produced  for 
commercial and residential use. The control system is programmed 
differently  for  commercial  and  residential  models. There  are  two 
differences in control system operation between the residential and 
commercial products:
•  Commercial  models  will  display  Tank  Temperature  on  the 
Desktop screen, residential models will not.
•  Commercial  models  can  regulate  tank  temperature  up  to  a 
maximum  of  180°F  (82°C),  residential  maximum  is  160°F 
(71°C).
control sYsteM navIGatIon
All  operational  information  and  user  settings  are  displayed  and 
accessed from the UIM. The UIM houses the control system's LCD 
(liquid crystal display) and five snap acting (momentary) user input 
buttons; an up, down and three multifunction operational buttons 
below the LCD, see Figure 35.
Operating Set Point 
  120°F
Status: Heating
MENU
HELP
GAS
OFF
O
N
MANUFACTURER / MODEL INFORMATION
LCD Screen
Information
Display
Status Icons
3 Operational buttons:
enter/exit menus,
select menu items,
activate adjustment modes,
confirm/cancel changes.
Up & Down buttons:
navigate menus,
adjust user settings
Title Bar
Operational buttons are multifunctional. Their current function is defined by
the text that appears directly above each button on the LCD screen.
UIM (user interface module)
Desktop Screen Shown
UP
DN
fIGure 35.
control sYsteM operatIon