ABOUT YOUR WATER HEATER 
TO TURN OFF THE WATER HEATER 
If it is necessary to turn off the water heater: 
• 
• 
Close the gas isolation valve at the inlet to the gas control. 
• 
Switch off the electrical supply at the isolating switch to the water heater 
(refer to note below). 
• 
Close the cold water isolation valve at the inlet to the water heater. 
Note: If there is a risk of freezing conditions, the electrical supply to the solar 
control unit should not be switched off unless the solar collectors are drained, 
otherwise damage could result (refer to 
 on page 10). 
 
TO TURN ON THE WATER HEATER 
• 
Open the cold water isolation valve fully at the inlet to the water heater. 
• 
If the solar collectors and solar hot and solar cold pipes have been drained, 
it will be necessary to bleed the collector circuit (refer to 
• 
If the electrical supply to the water heater has been switched off, switch on 
the electrical supply at the isolating switch. The isolating switch must be 
switched on for the solar control unit to operate and solar gain to be 
achieved. 
• 
Open the gas isolation valve fully at the inlet to the gas control. 
• 
Light the water heater (refer to 
• 
 
HOW DO I KNOW IF THE WATER HEATER IS INSTALLED CORRECTLY? 
Installation requirements are 
34. The water heater must be 
installed by an authorised person and the installation must comply with National 
Standards AS/NZS 3500.4, AS/NZS 3000, AS 5601 and all local codes and 
regulatory authority requirements. In New Zealand, the installation must 
conform with the Code of Practice for installation of Gas Appliances NZS 5261 
and the New Zealand Building Code. The timer is not weatherproof and must 
be installed indoors.