ABOUT YOUR WATER HEATER 
PIPE WORK AND INSULATION 
The solar hot and solar cold pipe work between the solar storage tank and the 
solar collectors MUST BE of copper and fully insulated with closed cell polymer 
insulation or similar (minimum thickness 13 mm). The insulation must be 
weatherproof and UV resistant if exposed. The insulation is essential to assist 
in providing freeze protection, will offer corrosion protection to a metal roof 
against water runoff over the copper pipe, assist in avoiding accidental contact 
with the solar pipe work and also reduce pipe heat losses. 
 
The insulation must be fitted up to the connections on both the solar collectors 
and the solar storage tank, as very high temperature water can flow from the 
solar collectors to the solar storage tank under certain conditions. 
 
Plastic pipe MUST NOT be used, as it will not withstand the temperature and 
pressure of the water generated by the solar collectors under certain conditions 
 
DOES THE WATER QUALITY AFFECT THE WATER HEATER? 
The water heater is suitable for most public water supplies, however some 
water qualities may have detrimental effects on the cylinder, solar collectors 
and fittings. If you are in a known harsh water area 
56. 
If you are not sure, have your water quality checked against the conditions 
56
 
HOW LONG WILL THE WATER HEATER LAST? 
There are a number of factors that will affect the length of service the water 
heater will provide. These include the water quality, the water pressure, 
temperature (inlet and outlet) and the water usage pattern. However, your 
water heater is supported by a comprehensive warranty 
 
ANODE PROTECTION 
The anode(s) installed in your water heater will slowly dissipate whilst 
protecting the cylinder. The life of the water heater cylinder may be extended 
by arranging for an authorised person to inspect the anode(s) and replacing it if 
required. 
 
The suggested time after installation when the anode(s) should be inspected is 
8 years. 
 
For softened water supplies or in areas of poor water quality, it is 
recommended the anode be inspected 3 years earlier than shown (refer to