ABOUT YOUR WATER HEATER 
10 
FREEZE PROTECTION 
The system when installed in areas subject to freeze conditions must be 
installed with the solar hot and solar cold pipes fully insulated with closed cell 
polymer insulation (minimum thickness 13 mm) to offer protection against 
freeze damage. Freeze conditions occur below 6
°C. The system has NO 
WARRANTY for freeze damage when installed above 400 metres altitude or if 
the solar hot and solar cold pipes are uninsulated (refer to 
 on page 59 and to 
 
The anti freeze control is designed to recirculate a small amount of water from 
the solar storage tank through the solar pipe work during periods of low 
temperatures. This is to prevent the water inside the pipe work from freezing. It 
is essential that the electrical circuit to the solar control unit is continually turned 
on if there is a risk of freezing. The solar warranty does not cover damage 
caused by freeze conditions when the electrical circuit to the solar control unit 
is turned off or interrupted. 
 
Notes: 
• 
If it is necessary to switch the power off to the solar control unit and there is 
a risk of freezing, then it is necessary to have your plumber drain the solar 
collectors and solar flow and return pipe work. 
• 
The freeze protection system will be rendered inoperable if electrical power 
is not available at the water heater. Damage caused by freezing due to no 
power at the water heater, is not covered by warranty. 
• 
Pipe work between the solar collectors and solar storage tank must be 
insulated. 
• 
The system is not covered for freeze damage above 400 metres altitude. 
•