Справочник Пользователя для Rheem Water Heater

Скачать
Страница из 63
 
INSTALLATION – SOLAR STORAGE TANK 
 
THIS WATER HEATER IS FOR OUTDOOR INSTALLATION ONLY. 
THIS WATER HEATER IS NOT SUITABLE FOR POOL HEATING. 
Check the water heater is suitable for the gas type available. 
(refer to the rating label on the water heater) 
 
The system is suitable for installation with Rheem NPT 200 solar collectors. 
The system is not suitable for installation above 400 metres altitude. 
 
The system when installed in areas subject to freeze conditions must be 
installed with the solar hot and solar cold pipes fully insulated with closed cell 
polymer insulation (minimum thickness 13 mm) to offer protection against 
freeze damage. Freeze conditions occur below 6
°C. The system has NO 
WARRANTY for freeze damage when installed above 400 metres altitude or if 
the solar hot and solar cold pipes are uninsulated (refer to 
Thicker insulation may be required to comply with the requirements of 
AS/NZS 3500.4. 
 
SOLAR WATER HEATER STORAGE TANK LOCATION 
The solar storage tank should be installed close to the most frequently used 
outlet and its position chosen with safety and service in mind. Make sure 
people (particularly children) will not touch the flue outlet. The flue terminal 
must be clear of obstructions and shrubbery. 
 
Consideration must also be given to the position of the solar storage tank in 
relation to the solar collectors. There are limitations on the maximum length of 
the solar hot and solar cold pipes between the solar storage tank and the solar 
collectors. Refer to 
 on page 36 and to 
 
on page 37. 
 
Clearance must be allowed for 
servicing of the solar storage tank. The 
solar storage tank must be accessible 
without the use of a ladder or scaffold. 
Make sure the temperature pressure 
relief valve lever is accessible and the 
access covers and burner can be 
removed for service. 
 
 
 
If possible leave headroom of one 
water heater length so the anode can 
be inspected or replaced. Remember 
you may have to remove the entire 
solar storage tank later for servicing. 
26