INSTALLATION – SOLAR STORAGE TANK 
31 
• 
water will be supplied to the cold water inlet of the temperature limiting 
device at a temperature exceeding the maximum recommended water 
supply temperature, or 
• 
when the hot taps are closed no water will be supplied to the cold water 
inlet of the temperature limiting device whilst hot water will continue to be 
supplied to the hot water inlet of the temperature limiting device. 
 
These conditions may result in either water at a temperature exceeding the 
requirements of AS/NZS 3500.4 being delivered to the hot water outlets in the 
ablution areas, or the device closing completely and not delivering water at all, 
or the device failing. Under either condition, the operation and performance of 
the device cannot be guaranteed. 
 
 
 
 
Circulated Hot Water Flow and Return System – Solar Water Heater 
 
REDUCING HEAT LOSSES 
The cold water line to and the hot water line from the water heater must be 
insulated in accordance with the requirements of AS/NZS 3500.4. The 
insulation must be weatherproof and UV resistant if exposed. 
 
The pipe work between the solar storage tank and the solar collectors must be 
fully insulated with closed cell polymer insulation or similar (minimum thickness 
13 mm). Thicker insulation may be required to comply with the requirements of 
AS/NZS 3500.4. The insulation must be weatherproof and UV resistant if 
exposed. The insulation must be fitted up to the connections on both the solar 
storage tank and the solar collectors.