INSTALLATION – SOLAR STORAGE TANK 
29 
HOT WATER DELIVERY 
This water heater can deliver water at temperatures which can cause scalding. 
 
It is necessary and we recommend that a temperature limiting device be fitted 
between the water heater and the hot water outlets in any ablution area such 
as a bathroom or ensuite, to reduce the risk of scalding. The installing plumber 
may have a legal obligation to ensure the installation of this water heater meets 
the delivery water temperature requirements of AS/NZS 3500.4 so that scalding 
water temperatures are not delivered to a bathroom, ensuite or other ablution 
area. 
 
Where a temperature limiting device is installed adjacent to the solar water 
heater, the cold water line to the temperature limiting device can be branched 
off the cold water line either before or after the isolation valve and pressure 
limiting valve to the solar storage tank, but it MUST BE before the non return 
valve. If an expansion control valve is required, it must always be installed after 
the non return valve and be the last valve prior to the solar storage tank. 
 
 Warning: A non return valve MUST BE installed on the cold water line to 
the solar storage tank AFTER the cold water branch to a temperature limiting 
device. Due to the higher water temperatures generated under certain 
conditions in the solar collectors of this solar water heater, an additional 
effective back-flow prevention device also should be used as an extra 
safeguard. Valve manufacturer RMC recommends Dual Check Valve model 
N7150, as being suitable for this application. 
 
 
 
 
Two Temperature Zones Using a Temperature Limiting Device