Справочник Пользователя для Emerson 308014EN

Скачать
Страница из 166
8-3
Rosemount Tank Radar REX
Chapter 8 Junction Boxes
Installation Manual
308014EN, Edition 4
May 2013
8.2
Junction Boxes for Intrinsically Safe and EEX e environments
Figure 8-3.
Intrinsically Safe and Explosion Proof Junction 
Boxes.
8.2.1
JB 140-15 for EEx i environments
JB 140-15 (EEx i) is used when a DAU or an RDU 40 is located more 
than 2 m away from the RTG and should only be used for intrinsically 
safe connections.
JB 140-15 has 15 terminals and has six openings for M25 glands, 
suitable for 9-16 mm cable diameter.
8.2.2
JB 140-11 for EEx e environments
JB 140-11 (EEx e) is used to connect power and the TRL/2 Bus to the 
RTG.
JB 140-11 contains 15 terminals and has five openings for M25 glands, 
suitable for 9-16 mm cable diameter (see Fig. 8-3).
Note!
JB140-15 is not approved for all markets.
DAU / RDU
TRL/2 Bus, 
Analog 
outputs, 
Relay 
output, 
Power 230/
115 VAC
JB 140-15
(EEX i)
JB 140-11
(EEX e)
~ 2 m cable 
with 
protective 
hose
~ 2 m cable with 
protective hose
Cable
JB_general_ed3
5 x M25