Справочник Пользователя для Emerson 308014EN
Rosemount Tank Radar REX
Chapter 8 Junction Boxes
Chapter 8 Junction Boxes
8-4
Installation Manual
308014EN, Edition 4
May 2013
8.2.3
Junction Boxes with Conduit Outlets
Figure 8-4.
Connection to rigid pipes via a junction box with
conduit outlets.
conduit outlets.
In the US wires from the transmitter head must be enclosed in a
protective steel braided hose.
protective steel braided hose.
Further connection to conduit pipes requires an explosion proof junction
box with L or T-shaped outlets, both variants available with 12 or 15-pin
terminal blocks for wiring.
box with L or T-shaped outlets, both variants available with 12 or 15-pin
terminal blocks for wiring.
The three-feet hose (EXP-FLEX), and junction boxes (GUA-L and GUA-
T) are optional, and can by request be supplied together with the
TankRadar Rex gauge.
T) are optional, and can by request be supplied together with the
TankRadar Rex gauge.
Note!
The junction box can be installed directly on the transmitter head by
using a suitable adapter with 3/4-inch male fitting facing the transmitter
head outputs.
using a suitable adapter with 3/4-inch male fitting facing the transmitter
head outputs.
US_jb_2
EXP-FLEX
GUA-L
GUA-T
Rigid
conduit
pipes
Transmitter head
with 3/4 inch
female output