8. ELECTRIC MECHANISM 
 
-5-2. Operation panel DIP switches (KE-436B, 436C) 
Note: 
Always turn off the power before setting the DIP switches.
 
 
KE-430B, 430C series
 
148
 
1086Q 
All DIP switches are set to OFF at the time of 
shipment. 
DIP switch A 
Switch 
Motion when set to ON 
DIPA-1 
Work clamp does not automatically lift after 
sewing is completed. 
DIPA-2 
Pedal mode is switched. 
See “8-8. Setting the work 
clamp mode” 
DIPA-3 - 
DIPA-4 - 
DIPA-5 
After sewing is completed, work clamp does not automatically rise. (only in split 
mode) 
DIPA-6 
Clamping force output is produced. (Inner clamping device available as an option) 
DIPA-7 - 
DIPA-8 
Thread breakage detector device is activated (available as an option). 
DIP switch B 
Switch 
Motion when set to ON 
DIPB-1 
Single split mode activated 
DIPB-2 - 
DIPB-3 
Thread is not trimmed after an emergency stop. 
DIPB-4 
Needle cooler output is produced. (Needle cooler available as an option) 
DIPB-5 
When a rotating-type thread breakage detector device is used, detection precision 
is increased from 8 to 14. 
When a fiber-type thread breakage detector device is used, detection precision is 
increased from 5 to 10. 
DIPB-6 
Fiber-type thread breakage detector device is ON, and DIP switch A-8 is ON 
(available as an option). 
DIPB-7 - 
DIPB-8 -