EXCESSIVE AIR PRESSURE 
STATIC SPARK
HAZARDOUS MATERIALS
HAZARDOUS PRESSURE
WARNING
 
EXCESSIVE AIR PRESSURE. Can cause per- 
sonal injury, pump damage or property damage.
Be sure material hoses and other components are able to 
withstand fluid pressures developed by this pump. Check all 
hoses for damage or wear. Be certain dispensing device is 
clean and in proper working condition.
Do not exceed the maximum inlet air pressure as stated on 
the pump model plate.
WARNING  STATIC SPARK. Can cause explosion resulting 
in severe injury or death. Ground pump and pumping 
system. 
Sparks can ignite flammable material and vapors.  
The pumping system and object being sprayed must be 
grounded when it is pumping, flushing, recirculating or 
spraying flammable materials such as paints, solvents, 
lacquers, etc. or used in a location where surrounding atmo-
sphere is conducive to spontaneous combustion. Ground the 
dispensing valve or device, containers, hoses and any object 
to which material is being pumped.
Secure pump, connections and all contact points to avoid vi-
bration and generation of contact or static spark.
Consult local building codes and electrical codes for spe-
cific grounding requirements.
After grounding, periodically verify continuity of electrical 
path to ground. Test with an ohmmeter from each compo-
nent (e.g., hoses, pump, clamps, container, spray gun, etc.) 
to ground to insure continuity. Ohmmeter should show 0.1 
ohms or less.
Submerse the outlet hose end, dispensing valve or device 
in the material being dispensed if possible. (Avoid free 
streaming of material being dispensed.)
Use hoses incorporating a static wire.
Use proper ventilation.
Keep inflammables away from heat, open flames and 
sparks.
Keep containers closed when not in use.
WARNING  Pump exhaust may contain contaminants. 
Can cause severe injury. Pipe exhaust away from work area 
and personnel.
In the event of a diaphragm rupture, material can be forced 
out of the air exhaust muffler.
Pipe the exhaust to a safe remote location when pumping 
hazardous or inflammable materials.
Use a grounded 3/8” minimum i.d. hose between the pump 
and the muffler.
WARNING  HAZARDOUS PRESSURE. Can result in serious 
injury or property damage. Do not service or clean pump, 
hoses or dispensing valve while the system is pressurized.
Disconnect air supply line and relieve pressure from the 
system by opening dispensing valve or device and / or 
carefully and slowly loosening and removing outlet hose or 
piping from pump.
WARNING  HAZARDOUS MATERIALS. Can cause serious 
injury or property damage. Do not attempt to return 
a pump to the factory or service center that contains 
hazardous material. Safe handling practices must comply 
with local and national laws and safety code requirements.
Obtain Material Safety Data Sheets on all materials from 
the supplier for proper handling instructions.
WARNING  EXPLOSION HAZARD. Models containing 
a l u m i n u m   w e t t e d   p a r t s   c a n n o t   b e   u s e d   w i t h 
1,1,1-trichloroethane,  methylene  chloride  or  other 
halogenated hydrocarbon solvents which may react and 
explode.
Check pump motor section, fluid caps, manifolds and all 
wetted parts to assure compatibility before using with sol-
vents of this type.
CAUTION  Verify the chemical compatibility of the pump 
wetted parts and the substance being pumped, flushed 
or recirculated. Chemical compatibility may change with 
temperature and concentration of the chemical(s) within 
the substances being pumped, flushed or circulated. 
For specific fluid compatibility, consult the chemical 
manufacturer.
CAUTION   Maximum  temperatures  are  based  on 
mechanical stress only. Certain chemicals will significantly 
reduce maximum safe operating temperature. Consult 
the chemical manufacturer for chemical compatibility and 
temperature limits. Refer to PUMP DATA on page 1 of this 
manual.
CAUTION  Be certain all operators of this equipment 
have been trained for safe working practices, understand 
it’s limitations, and wear safety goggles / equipment when 
required.
CAUTION  Do not use the pump for the structural 
support of the piping system. Be certain the system 
components are properly supported to prevent stress on 
the pump parts.
Suction and discharge connections should be flexible con-
nections (such as hose), not rigid piped, and should be com-
patible with the substance being pumped.
CAUTION  Prevent unnecessary damage to the pump. 
Do not allow pump to operate when out of material for 
long periods of time.
Disconnect air line from pump when system sits idle for 
long periods of time.
CAUTION  Use only genuine ARO replacement parts to 
assure compatible pressure rating and longest service life.
NOTICE
 Replacement warning labels are available 
upon request: “Static Spark PN \ 931 & Diaphragm 
Rupture PN \ 93616-1.”
NOTICE
  RE-TORQUE  ALL  FASTENERS  BEFORE 
OPERATION. Creep of housing and gasket materials may 
cause fasteners to loosen. Re-torque all fasteners to insure 
against fluid or air leakage.
WARNING
Hazards or unsafe practices which 
could result in severe personal injury, 
death or substantial property damage.
CAUTION
Hazards or unsafe practices which 
could result in minor personal in-
jury, product or property damage.
NOTICE
Important installation, operation or
maintenance information.
OPERATING AND SAFETY PRECAUTIONS
READ, UNDERSTAND, AND FOLLOW THIS INFORMATION TO AVOID INJURY AND PROPERTY DAMAGE.