MAINTENANCE
When the Sensor detects a user, the water 
immediately starts to flow. Water flow will stop Two 
seconds after user is out of sensor range. The off delay 
allows the user to comfortably move his hands without 
the flow cycling on to off. As a precaution, a safety 
timer will turn off the water, after the sensor has been 
blocked for 59 seconds. The water will stay off until the 
blockage is removed from the detection zone.
Detection Zone: 2" - 10" (50mm - 250mm)
Default: Set at Factory 6" (150mm)
6
    HAND WASH SENSOR OPERATION;
Fig. 1
1
1.  Setting the Detection Zone (Distance):
Remove cover from ENCLOSURE. Disconnect GRAY 
SENSOR WIRE 
(1) from circuit board, then reconnect.
2. While the SENSOR CONTROL LED (2) is blinking 
slowly, place your hand 1 - 2 in. (30-50mm) in front of 
the sensor. 
Fig. 2a.
3. When the LED stops blinking and stays "ON", move 
your hand to the desired position and hold in place until 
the LED begins to blink again. 
Fig. 2a.
4. Once the SENSOR CONTROL LED (2) begins to 
blink again, remove your hand from the detection zone. 
When the flashing stops, the detection distance is set.
    HOW TO CHANGE SENSOR
RANGE; (Factory set at 6") Fig. 2
2
Fig. 2
Fig. 2a
DETECTION
ZONE
Fig 1
1" - 2" (30mm - 50mm
BLINKING LED
2
2
Fig. 2a
Fig. 2a
BLINKING LED
2
UP TO 10"
(250mm)
1. Remove AERATOR HOUSING (1) with KEY supplied 
with faucet.
3. Remove AERATOR (2) from HOUSING (1).
2. Clean the AERATOR SCREENS (3) with a old tooth 
brush to remove dirt.
4. Rinse Clean with water. Reassemble and install into 
spout end. Be sure black seal washer is in place.  
    HOW TO CLEAN AND REMOVE
THE AERATOR; Fig. 3
3
2
3
1