Q:  How will I know if battery needs  to be replaced?
A:  Valve does not open and sensor blinks 2 times 
interrupted by pause for up to 7 days.
Q:  Why has the flow rate of the faucet reduced 
significantly?
A: Check and clean aerator and strainer.
Q:  There is no flow out of faucet when I'm in the 
sensor range?
A: Check sensor. If sensor blinks 2 times interrupted by 
pause, replace battery, or call 1800-442-1902. 
Q:  Why does the faucet operate the opposite of 
expected-Turns On when not in sensor range, but turns 
off when in sensor range?
A: Sensor wires to solenoid are reversed. Black to - 
& Red to + is correct.
Q:  What is the normal operating pressure range?
A:   Faucet will operate with supply pressures ranging 
from 20-80 psi.