Operation 
 
-12- 
 
Q-Wash 360Z-LED User Manual Rev. 01g 
Continued from previous page 
 
Move-in Black 
 
This option allows you to activate or deactivate the move-in black 3-seconds delay. 
1)   Go to MENU > SPECIAL > BLACK 
2)   Select YES to enable the 3 seconds delay or NO to make the blackout immediate. 
 
 
 
Power 
 
You may use this function to boost the output power for specific, short-term applications. 
1)  Go to MENU > SPECIAL > POWER
2)  Select NORMAL or HIGH
 
 
 
 
 
The fixture will return to Normal if the LEDs’ temperature becomes too high. 
 
 
 
Color Settings 
 
The COLOR setting determines how the Q-Wash 360Z-LED generates the white color 
based on various RGB settings. 
1)  Go to MENU > SPECIAL > COLOR
2)  Select OFFRGBTOW, or UC
 
 
 
 
 
UC:  When the RGB faders are all set to “255”, the output matches that of less 
efficient fixtures (Universal Color). 
RGBTOW:  When the RGB faders are all set to “255”, the resulting output is defined by  
RGB-W (see MENU > EXTRA > CALIB). 
OFF:  When the RGB faders are all set to “255”, the output is maximum, although 
the resulting white color may not be balanced. 
 
 
 
Fan Control 
 
This option defines how you can control the fan speed, whether with the DMX controller or 
only from the control panel.  
1)   Go to MENU > SPECIAL > FAN
2)   Select DMX or SYSTEM
 
 
 
 
 
DMX:  Enables the DMX controller to control the fan speed (Control function). 
SYSTEM:  Restricts the control of the fan speed to the control panel.. 
 
 
 
Color Calibration 
 
If necessary, you may adjust the color temperature of each of the macros (White1~11). 
1)   Go to MENU > EXTRA.  
2)  Press <ENTER> (PASSWORD) will show on the display. 
3)   Press <ENTER> (**** will show on the display). 
4)  Enter the password, as explained in Keylock (CALIB will show on the display).  
5)   Press <ENTER> (3200K will show on the display). 
6)  Use <UP> or <DOWN> to select another color temperature (3400~10000 K), or press 
<ENTER> to edit the current temperature. 
7)  Select REDGREEN, or BLUE
8)  Select a value (000~255). 
9)  Repeat for the other colors. 
 
 
 
 
 
 
 
 
 
 
 
Continues on the next page