4. OPERATION AND DISPLAY
4.3 Drive unit display
4.3.1 Drive unit display sequence
Use the display (5-digit, 7-segment LED) on the front panel of the servo amplifier for status display,
parameter setting, etc. Set the parameters before operation, diagnose an alarm, confirm external
sequences, and/or confirm the operation status.
The automatic scroll mode is selected at power-on. Before starting use, therefore, press the "UP" or
"DOWN"
 button to change the fifth digit to the necessary slot number "1" to "8" and press the "MODE"
button for 2s or more to change the indication.
Press the "MODE" "UP" or "DOWN" button once to move to the next screen.
To refer to or set the expansion parameters, make them valid with DRU parameter No. 19 (parameter
write disable).
UP
DOWN
MODE
Status display
Diagnosis
Alarm
Basic DRU
parameters
Expansion DRU
parameters 1
Expansion DRU
parameters 2
Cumulative feedback
pulses [pulse]
Current alarm
Motor speed
[r/min]
Droop pulses 
[pulse]
Cumulative command
pulses [pulse]
Command pulse
frequency [kpps]
Effective load ratio
[%]
Peak load ratio
[%]
Instantaneous torque
[%]
Within one-revolution
position low [pulse]
Within one-revolution
position, high [100 pulses]
ABS counter
[rev]
Load inertia moment
ratio [times]
Software version
Low 
Software version
High 
Motor series ID
Motor type ID
Encoder ID
Last alarm
Second alarm in past  
Third alarm in past 
Fourth alarm in past 
Fifth alarm in past
Sixth alarm in past 
Parameter error No.  
Drive unit external 
input signal
Drive unit external 
output signal
Drive unit output signal 
(DO) forced output
DRU parameter No. 1
DRU parameter No. 0
DRU parameter No. 20
DRU parameter No. 21
DRU parameter No. 50
DRU parameter No. 51
DRU parameter No. 18
DRU parameter No. 19
DRU parameter No. 48
DRU parameter No. 49
DRU parameter No. 83
DRU parameter No. 84
button
(Note)
@
@
@
@
@
@
@
@
@
@
@
@
@
@
@
@
@
@
@
@
@
@
@
@
@
@
@
@
@
@
@
@
@
@
@
@
@
@
@
@
Note 1. @ indicates the slot number.
         2. The parameter display range varies with the parameter write inhibit.