4. OPERATION 
 
(2) Timing chart 
In the following timing chart, operation is performed group-by-group in accordance with the values set 
in point table No.1. 
Transmission data
Station 0
Servo motor 
speed
1)
2)
4)
5)
7)
8)
10)
Station 1
Servo motor 
speed
Station 2
Servo motor 
speed
Station 3
Servo motor 
speed
Station 4
Servo motor 
speed
Station 5
Servo motor 
speed
Station 6
Servo motor 
speed
Station 7
Servo motor 
speed
Station 8
Servo motor 
speed
Station 9
Servo motor 
speed
Group a
Group b
Group c
Group d
3)
6)
9)
11)
12)
 
No. 
Transmission data 
Command 
Data No. 
1) 
Selection of point table No.1 of group a 
[9] [2] 
[6] [0] 
2) 
Forward rotation start (ST1) ON 
[9] [2] 
[6] [0] 
3) 
Forward rotation start (ST1) OFF 
[9] [2] 
[6] [0] 
4) 
Selection of point table No.1 of group b 
[9] [2] 
[6] [0] 
5) 
Forward rotation start (ST1) ON 
[9] [2] 
[6] [0] 
6) 
Forward rotation start (ST1) OFF 
[9] [2] 
[6] [0] 
7) 
Selection of point table No.1 of group c 
[9] [2] 
[6] [0] 
8) 
Forward rotation start (ST1) ON 
[9] [2] 
[6] [0] 
9) 
Forward rotation start (ST1) OFF 
[9] [2] 
[6] [0] 
10)  Selection of point table No.1 of group d 
[9] [2] 
[6] [0] 
11)  Forward rotation start (ST1) ON 
[9] [2] 
[6] [0] 
12)  Forward rotation start (ST1) OFF 
[9] [2] 
[6] [0] 
In addition, parameter values common to the stations of each group can be written and alarm reset 
can be made, for example. 
 
(3) Group setting instructions 
Only one servo amplifier may send a reply in any group. If two or more servo amplifiers send reply 
data at the same time, they may become faulty.