4 -  6 
4. OPERATION 
 
(2) Point table 
(a) Point table setting 
Up to 15 point tables may be set. To use point table No.s 4 to 31, however, the point table No. 
selection 3 (DI2), point table No. selection 4 (DI3) and point table No. selection 5 (DI4) should be 
made valid in "I/O Devices" on the MR Configurator (servo configuration software). 
Set the point tables using the MR Configurator (servo configuration software) or the servo 
amplifier operation section. 
The following table lists what to set. Refer to section 4.2.2, section 4.2.3 and section 4.2.4 for details 
of the settings. 
Name Description 
Position data 
Set the position data for movement. 
Servo motor speed 
Set the command speed of the servo motor for execution of positioning. 
Acceleration time constant 
Set the acceleration time constant. 
Deceleration time constant 
Set the deceleration time constant. 
Dwell 
Set the waiting time when performing automatic continuous operation. 
Auxiliary function 
Set when performing automatic continuous operation. 
 
(b) Selection of point table 
Using the input signal or communication function, select the point table No. with a command from 
the command device (controller) such as a personal computer. 
The following table lists the point table No. selected in response to the input signals/commands. 
Note that when the input signals are used, the point tables used as standard are No.1 to 3. To use 
No.4 to 31, the point table No. selection 3 (DI2), point table No. selection 4 (DI3) and point table 
No.  selection  5  (DI4)  should  be  made  valid  in  "I/O  Devices"  (Refer  to  chapter  6)  on  the  MR 
Configurator (servo configuration software). 
When the communication function is used to select the point tables, refer to chapter 15 for details 
of the command transmission method, etc.