4 -  28 
4. SIGNALS AND WIRING 
 
4.6.2 Movement completion rough match in position 
POINT 
 
If an alarm cause, etc. are removed and servo-on occurs after a stop is made 
by servo-off, alarm occurrence or Forced stop (EMG) ON during automatic 
operation, Movement completion (MEND), Rough-match, (CPO) and In 
position (INP) are turned on. To resume operation, confirm the current 
position and the selected point table No. for preventing unexpected operation. 
 
(1) Movement completion 
The following timing charts show the output timing relationships between the position command generated 
in the servo amplifier and the movement completion (RYnC). This timing can be changed using parameter 
No.PA10 (in-position range). RYnC turns ON in the servo-on status. 
Forward rotation start (RYn1)
or reverse rotation start (RYn2)
Position command and 
servo motor speed
3ms or less
In-position range
Servo motor speed
Position command
OFF
ON
OFF
ON
Forward 
rotation
 
  0r/min
Movement completion (RXnC)
 
When parameter No.PA10 is small 
 
Forward rotation start (RYn1)
or reverse rotation start (RYn2)
Position command and 
servo motor speed
3ms or less
In-position range
Servo motor speed
Position command
OFF
ON
OFF
ON
Forward 
rotation
 
  0r/min
Movement completion (RXnC)
 
When parameter No.PA10 is large